Chapter 6 List of Parameters
70
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
b1.08 AVR function
0: Disable
1: Enable all the time
2: Disabled in Dec process
1
2
X 0 2
b1.09 VF Output Voltage
Selection
0: None
1: AI1
2: AI2
3: Keyboard potentiometer
1
0
X 0 3
b1.10 VF Output Voltage
Offset Selection
0: None
1: AI1
2: AI2
3: Keyboard potentiometer
1
0
X 0 3
Group b2.Enhanced parameters
b2.00 Carrier wave frequency
2.0 15.0KHz
0.1
8.0
O 20 150
b2.01 Auto adjusting of CWF
0: Disable
1: Enable
1
1
O 0 1
b2.02 Voltage adjustment
selection
: Over-voltage at
stall Selection
0: Disable
(When install brake resistor)
1: Enable
: Not stop when
instantaneous stop function selection
0: Disable
1: Enable
(Low voltage compensation)
: Over
modulation selection
0: Disable
1: Enable
1
001
X 0 111H
b2.03 Over voltage point atstall
120.0% 150.0%Udce
0.1%
140.0%
X 1200
1500
b2.04 Droop control
0.00 10.00Hz
0.00
0.00Hz
O 0 1000
b2.05 Auto current limiting
threshold
20.0% 200.0%Ie
0.1%
150.0%
X 200 2000
b2.06 Frequency decrease rate
when current limiting
0.00 99.99Hz/s
0.01
Hz/s
1.00Hz/s
O 0 9999
b2.07 Auto current limiting
selection
0: Invalid at constant speed
1: Valid at constant speed
Note: It is valid all the time at Acc/Dec
1
1
X 0 1
b2.08 Gain of Slip
compensation
0.0 300.0%
0.1%
100.0%
O 0 3000
b2.09 Slip compensation limit
0.0 250.0%
0.1%
200.0%
O 0 2500
b2.10 Slip compensation time
constant
0.1 25.0s
0.1s
2.0s
O 0 250
b2.11 Auto energy-saving
function
0: Disable
1: Enable
1
0
X 0 1