background image

KTM-1000 

 

 

                           

 

15 

 

 

.

 

故障排除

 

1.

 

定期校準

 

定期校準機體可以維持測試的高精準度

通常校準時期為

6-12

個月,如果快到應校準時期

請與代理商聯繫。

 

 

2.

 

恢復原廠設定

 

執行恢復原廠設定時需要先確保已先將電源拔掉

並按下機體後方的一個恢復原廠設定的按

鈕,按下恢復原廠設定按鈕之後,將電源插入充電端,測試儀會自動開機

(

不須再重新按開機

按鈕

)

,在開機之後,校正狀態與編輯資訊將會不變,不過設定功能等

...

時間與其它設置將重

置為原廠設定值。

 

 

3.

 

故障排除指南

 

 

 

 

問題

 

原因

 

解決方案

 

扭矩數值不一致

 

錯誤濾波設定

 

調整峰值濾波設定

 

沒有使用扭矩測試座

 

測試電動起子時一定要使用扭矩測試座

 

不斷更改使用電動起子的姿勢

 

確定電動起子使用姿勢正確

 

 

扭矩測試儀沒有固定妥當

 

確認扭矩測試儀有正確固定

 

測試電動起子無法維持穩定扭矩值

 

將電動起子送回檢測

 

扭矩測試儀需校準

 

將扭矩測試儀送回校準

 

機體會自動關機

 

低電量

 

將機體充電

 

休眠模式設定太短

 

調整休眠模式的設定

 

機體無法開機

 

低電量

 

將機體充電

 

顯示記憶體錯誤

 

執行恢復原廠設定

 

Содержание KTM-1000

Страница 1: ...UE METER INSTRUCTION MANUAL KTM 1000 KILEWS INDUSTRIAL CO LTD Y2F144 2 006 Note To prevent battery life decline for a long period of time without usetorque meter needs to activate the battery at least...

Страница 2: ...KTM 1000 1 2 2 3 3 4 4 4 5 6 6 7 8 11 11 11 11 12 12 12 12 13 13 14 14 14 14 15 15 15 15 16...

Страница 3: ...KTM 1000 2...

Страница 4: ...KTM 1000 3 1 1 4 M10 x 1 25 KTM 1000 KTM 1000 1 LCD 2 3 SD 4 5 Mini USB 6 KTM 1000 KTM 1000 KTM 1000 KTM 1000 24 KTM 1000 KTM 1000 SETTINGS CLOCK 24 KTM 1000 KTM 1000 1 2 KTM 1000 3 4 5 6 KTM 1000 5...

Страница 5: ...KTM 1000 4 1 2 KTM 1000 Power Off...

Страница 6: ...KTM 1000 5 3 Measure Mode Peak Track Quick Run Settings System Info Torque Calculator Auto Clear Sleep Mode Back Light Profiles Language Clock Brightness Auto Start Settings Lock PIN PIN 1234...

Страница 7: ...KTM 1000 6 1 Peak Track 1 2 1 1 3 1 Measure Mode 2 Peak Next 3 Next 4 1 2 USB 3 3 4...

Страница 8: ...KTM 1000 7 1 2 1 2 3 SD SD USB USB X 2 Peak Track Graph Clear Track 2 1 3 1 Quick Run 2 3...

Страница 9: ...KTM 1000 8 1 2 Graph 3 Clear 3 8 3 1 1 Settings 2 Profiles 3 4 Profile Status Units Target torque Variance Peak threshold Test Direction Filter...

Страница 10: ...KTM 1000 9 5 Profiles 6 Next 7 Status 8 ACTIVE OK 9 OK 10 Target torque 11 OK 12 Variance 13 10 14 Peak threshold 15 OK...

Страница 11: ...KTM 1000 10 16 Test Direction 17 OK 18 Filter 19 100 OK 20 Set ACTIVE Ft Lbs In Lbs In Oz Nm Kgf Cm Kgf m Gf Cm cNm 100kg 10 CW CCW Both Directions...

Страница 12: ...KTM 1000 11 4 System Info 5 Torque Calculator 6 Auto Clear 1 9 Off 7 Sleep Mode 1 40 Off...

Страница 13: ...KTM 1000 12 8 Back Light 30 8 Off 9 Language 10 Clock 11 Brightness...

Страница 14: ...KTM 1000 13 12 Auto Start None 13 Settings Lock PIN PIN 1234 13 1...

Страница 15: ...KTM 1000 14 1 KTM 1000 2 Belleville 3 6 2 3 6 2 3 6...

Страница 16: ...KTM 1000 15 1 6 12 2 3...

Страница 17: ...100N m 0 5 10 19 9N m 1 5 9 9N m 2 1 Cp Cpk Sigma SD 8 In Oz In Lb Ft Lb Nm cNm KgCm gfCm Kgm 8 12 KTM 1000 8 5 0 100 0 Nm 0 5 20 100 Nm 1 0 10 20 Nm 2 0 5 10Nm SD USB mini 3 7V 4400 mAh Lithium Ion...

Страница 18: ...erms 20 Display Features and Settings 21 23 Display Screen 21 Main Menu 21 Settings 22 23 Editing Profiles 24 Settings Lock 25 Measuring Torque 26 28 Collecting Torque Data 26 Using Quick Run 26 Using...

Страница 19: ...s unit unless you are an authorized service technician Always unplug unit before inspecting cleaning or performing maintenance on the unit Never perform maintenance on unit that is not in accordance w...

Страница 20: ...r Made in North America 1 year warranty Processes statistical calculations Cp Cpk Sigma On Screen graphing capability for tool performance analysis Export data to SD Card Automatic screen rotation lev...

Страница 21: ...ompt or further changes need to be made please go to the SETTINGS menu and select CLOCK adjustments Please note that the date on the included calibration certificate is the date that the tester was ca...

Страница 22: ...that a tool experiences Track Track mode is used to measure the amount of force that is applied to the transducer in real time Peak Filter The expected period of time needed to capture a peak millise...

Страница 23: ...en they want to power down the unit SystemInfo The system information menu allows the user to access various information about the unit including the software version the serial number battery informa...

Страница 24: ...ally shuts down the torque tester when it is not in use in order to conserve battery life The time before automatic shutdown can be set from 1 to 40 minutes using the numbers on the keypad or the feat...

Страница 25: ...g the numbers on thekeypad Brightness The brightness setting allows users to adjust the touch screen s level of brightness The brightness can be increased or decreased to the desired level by using th...

Страница 26: ...before they can be used Units The units in which torque will be measured when this profile is active Options are Ft Lbs In Lbs In Oz Nm Kgf Cm Kgf m Gf Cm and cNm Target Torque The desired torque valu...

Страница 27: ...dited but active profiles can be selected clock settings are locked but other settings can be adjusted Settings User is locked into a single profile clock settings are locked but other settings can be...

Страница 28: ...ap fastening Using Quick Run Quick run provides quick and simple access to the torque tester s measuring capability The arrows beneath the readout allow the user to select units of measurement and to...

Страница 29: ...ode screen pressing the graph icon will display statistics about thecollecteddataset Pressingthe red X icon will clear the data logged by the unit Data is exported to an SD card in the form of a Rich...

Страница 30: ...being used Remove the cover to reconfigure the washer stack by loosening the two set screws at the base of the cover and lifting it straight up Replace the cover and secure the set screws before placi...

Страница 31: ...eunit Sleep mode time set too short Adjustsleep mode time Unit will not turn on Lowbattery Rechargetheunit Flash memory error Perform hard reset CalibrationofUnit Periodic calibrations are required in...

Отзывы: