Troubleshooting Guide

 

 
 

 

Problem

 

Possible Cause

 

Solution

 

 

 

 

 

 

 

Inconsistent torque readings

 

Wrong filter set

 

Adjust peak time filter

 

Rundown joint not being used

 

Always use a rundown joint when 
testing power tools

 

 

Tool is not being held consistently

 

Ensure that driver is held securely 
and in the same plane for every 
rundown

 

Torque tester is not properly 
secured

 

Ensure that tester base is 
anchored  securely

 

Tool being tested is unable to 
hold consistent torque value

 

Send tool in for evaluation

 

Torque tester needs calibration

 

Send torque tester in for 
calibration

 

 

Unit turns off by itself

 

Low battery

 

Recharge the unit

 

Sleep mode time set too short

 

Adjust sleep mode time

 

 

Unit will not turn on

 

Low battery

 

Recharge the unit

 

Flash memory error

 

Perform hard reset

 

 

 

 

 

Calibration of Unit

 

 

Periodic calibrations are required in order to maintain a high standard of accuracy. In most applications a 
6-12  month calibration interval is acceptable. Please contact your local distributor or the manufacturer 
when your  unit is due for calibration. 

 

 

Performing a Hard Reset

 

 

A  hard  reset  can  be  performed  by  pressing  the  button  located  inside  the  hole  on  the  back  of  the 
torque  tester while the unit is unplugged. After the reset button has been pressed, the unit will not turn 
on  until  it  is  plugged  in  again.  The  calibration  state  and  profiles  will  remain  unchanged,  but  this 
operation will  reset the  clock and all other settings to their default values. 

 
 
 
 
 

 

Содержание KTM-1000

Страница 1: ...UE METER INSTRUCTION MANUAL KTM 1000 KILEWS INDUSTRIAL CO LTD Y2F144 2 006 Note To prevent battery life decline for a long period of time without usetorque meter needs to activate the battery at least...

Страница 2: ...KTM 1000 1 2 2 3 3 4 4 4 5 6 6 7 8 11 11 11 11 12 12 12 12 13 13 14 14 14 14 15 15 15 15 16...

Страница 3: ...KTM 1000 2...

Страница 4: ...KTM 1000 3 1 1 4 M10 x 1 25 KTM 1000 KTM 1000 1 LCD 2 3 SD 4 5 Mini USB 6 KTM 1000 KTM 1000 KTM 1000 KTM 1000 24 KTM 1000 KTM 1000 SETTINGS CLOCK 24 KTM 1000 KTM 1000 1 2 KTM 1000 3 4 5 6 KTM 1000 5...

Страница 5: ...KTM 1000 4 1 2 KTM 1000 Power Off...

Страница 6: ...KTM 1000 5 3 Measure Mode Peak Track Quick Run Settings System Info Torque Calculator Auto Clear Sleep Mode Back Light Profiles Language Clock Brightness Auto Start Settings Lock PIN PIN 1234...

Страница 7: ...KTM 1000 6 1 Peak Track 1 2 1 1 3 1 Measure Mode 2 Peak Next 3 Next 4 1 2 USB 3 3 4...

Страница 8: ...KTM 1000 7 1 2 1 2 3 SD SD USB USB X 2 Peak Track Graph Clear Track 2 1 3 1 Quick Run 2 3...

Страница 9: ...KTM 1000 8 1 2 Graph 3 Clear 3 8 3 1 1 Settings 2 Profiles 3 4 Profile Status Units Target torque Variance Peak threshold Test Direction Filter...

Страница 10: ...KTM 1000 9 5 Profiles 6 Next 7 Status 8 ACTIVE OK 9 OK 10 Target torque 11 OK 12 Variance 13 10 14 Peak threshold 15 OK...

Страница 11: ...KTM 1000 10 16 Test Direction 17 OK 18 Filter 19 100 OK 20 Set ACTIVE Ft Lbs In Lbs In Oz Nm Kgf Cm Kgf m Gf Cm cNm 100kg 10 CW CCW Both Directions...

Страница 12: ...KTM 1000 11 4 System Info 5 Torque Calculator 6 Auto Clear 1 9 Off 7 Sleep Mode 1 40 Off...

Страница 13: ...KTM 1000 12 8 Back Light 30 8 Off 9 Language 10 Clock 11 Brightness...

Страница 14: ...KTM 1000 13 12 Auto Start None 13 Settings Lock PIN PIN 1234 13 1...

Страница 15: ...KTM 1000 14 1 KTM 1000 2 Belleville 3 6 2 3 6 2 3 6...

Страница 16: ...KTM 1000 15 1 6 12 2 3...

Страница 17: ...100N m 0 5 10 19 9N m 1 5 9 9N m 2 1 Cp Cpk Sigma SD 8 In Oz In Lb Ft Lb Nm cNm KgCm gfCm Kgm 8 12 KTM 1000 8 5 0 100 0 Nm 0 5 20 100 Nm 1 0 10 20 Nm 2 0 5 10Nm SD USB mini 3 7V 4400 mAh Lithium Ion...

Страница 18: ...erms 20 Display Features and Settings 21 23 Display Screen 21 Main Menu 21 Settings 22 23 Editing Profiles 24 Settings Lock 25 Measuring Torque 26 28 Collecting Torque Data 26 Using Quick Run 26 Using...

Страница 19: ...s unit unless you are an authorized service technician Always unplug unit before inspecting cleaning or performing maintenance on the unit Never perform maintenance on unit that is not in accordance w...

Страница 20: ...r Made in North America 1 year warranty Processes statistical calculations Cp Cpk Sigma On Screen graphing capability for tool performance analysis Export data to SD Card Automatic screen rotation lev...

Страница 21: ...ompt or further changes need to be made please go to the SETTINGS menu and select CLOCK adjustments Please note that the date on the included calibration certificate is the date that the tester was ca...

Страница 22: ...that a tool experiences Track Track mode is used to measure the amount of force that is applied to the transducer in real time Peak Filter The expected period of time needed to capture a peak millise...

Страница 23: ...en they want to power down the unit SystemInfo The system information menu allows the user to access various information about the unit including the software version the serial number battery informa...

Страница 24: ...ally shuts down the torque tester when it is not in use in order to conserve battery life The time before automatic shutdown can be set from 1 to 40 minutes using the numbers on the keypad or the feat...

Страница 25: ...g the numbers on thekeypad Brightness The brightness setting allows users to adjust the touch screen s level of brightness The brightness can be increased or decreased to the desired level by using th...

Страница 26: ...before they can be used Units The units in which torque will be measured when this profile is active Options are Ft Lbs In Lbs In Oz Nm Kgf Cm Kgf m Gf Cm and cNm Target Torque The desired torque valu...

Страница 27: ...dited but active profiles can be selected clock settings are locked but other settings can be adjusted Settings User is locked into a single profile clock settings are locked but other settings can be...

Страница 28: ...ap fastening Using Quick Run Quick run provides quick and simple access to the torque tester s measuring capability The arrows beneath the readout allow the user to select units of measurement and to...

Страница 29: ...ode screen pressing the graph icon will display statistics about thecollecteddataset Pressingthe red X icon will clear the data logged by the unit Data is exported to an SD card in the form of a Rich...

Страница 30: ...being used Remove the cover to reconfigure the washer stack by loosening the two set screws at the base of the cover and lifting it straight up Replace the cover and secure the set screws before placi...

Страница 31: ...eunit Sleep mode time set too short Adjustsleep mode time Unit will not turn on Lowbattery Rechargetheunit Flash memory error Perform hard reset CalibrationofUnit Periodic calibrations are required in...