3
2
Sequence Type
1. “OKALL signal” output mode when the
“Sequence Type” is “Single” or “Multiple” .
2. Turn OFF/ON Sequence Loop Function.
OFF: (1)Sequence process controlled by
“DAS” or “AMS” system.
(2) Turn OFF Sequence Loop Function.
Single :
(1) “OKALL signal” output after
finished each “Sequence” .
(2) Turn ON Sequence Loop Function.
Multiple :
(1) “OKALL signal” output after
finished the “Job” .
(2) Turn ON Sequence Loop Function
NOTE:
In “Single” or“ Multiple” mode, “ASM”
system cannot switch the programs
and tools execution order externally
OFF
Single
Multi
OFF
Product Serial
Number
Display controller’s serial number
NA
controller’s serial
number
Auto Learning
Auto Learning:
To enable the automatic learning function,
you need to set “
P
” and “
T
” first. After the
auto-learning is completed (there is a braking
action), you will know which program and
which tool the data to store. The screen will
display three kinds of data for tools, as
“
Time
”, “
Torque”
& “
Thread”
(The three
data cannot be 0, to save the parameters after
automatic learning)
1~99(Pro)
1~5(Tool)
O1
NA
Gate Mode
Once: One-time artifacts are in place
Twice: Two-time artifacts are in place
None: Do not start this mode
Once/Twice/None None
Reverse Mode
Set reverse countdown function
Once: Reverse countdown only once
Each: Count down each reverse rotation
Once/Each
Once
Batch Mode
Set counter function
DEC: countdown; INC: count up
DEC/INC
DEC
Device Time
Set controller time
Year/month/day/hour/minute/second
NA
NA
Network Mode
Select data output by WLAN
、
LAN
or RS-232
WLAN / LAN /
RS-232
RS-232