31
4. Control Setting
Name
Function Explanation
Set Value Options
Default Setting
Operation Mode
STD: Stand-alone mode
ADV: KL-AMS Network system
(wireless/wired) connection mode
STD/ADV
STD
Device ID
Set the device number
1~99
01
Edit Unit
Unit = P Tool
Press “Enter” key and then set “Program” and
“Tool”
1~99(Unit)
1~99(Pro)
1~5(Tool)
01
01
01
Job Edit /
Total Sequence
Set the “
Job
” for the Sequence first, and then
the quantity of “
Total Sequence”
for each job
1~20(Job)
1~20(Seq)
01
01
SEQ. Edit
Set the “Job” for the Sequence first and then
the quantity of “
Unit”
and “
OF. (offset)”
for
each “
S
”
1~20(Job)
1~20(Seq)
1~99(Unit)
+99.99~
–99.99
(offset)
01
01
01
+00.00
Call Job
Select the program of job to start locking
0~20 (Job)
00
Factory Default
Restore to factory status and clear all memory
data
Y/N
N
Torque Unit
Set torque display unit
Kgf.cm
N.m
Kgf.m
Lbf.in
Kgf.cm
Brake Signal
After jump off, the duration of brake signal
Keep: Continue to next startup and then
disappear
Release: Disappear as soon as hand-panel is
released
Keep/Release
Keep
Barcode Enable
Switch "Job" with the barcode stored in the
controller
OFF : Turn off barcode switching
ON : Turn on barcode switching
OFF/ON
OFF
Save/Scan Job
Barcode
Select the work program, switch the bar code
used by the work program, each group of bar
codes cannot exceed 20 bytes.
1~20
01
Barcode Setting
First set the “Job”
From: Set the bar code to judge from the first
few characters.
Count: There are a few judgment characters
from the number of characters to be judged.
NA
NA
Change Password Set password lock
0000~9999
0000