8-4 Specifications
PLZ-U
*1. Fixed value
*2. Time to reach from 10 % to 90 % when the current is changed from 2 % to 100 % of the rated current of H range.
Model
PLZ150U
PLZ70UA
Switching mode
Operation mode
CC and CR
Selectable frequency range
1 Hz to 20 kHz
Duty cycle setting
2 % to 98 %, 0.1 % steps
Frequency resolution
1 Hz to less than 1 kHz
1 Hz
1 kHz to less than 10 kHz
10 Hz
10 kHz to 20 kHz
100 Hz
Accuracy of frequency setting
±(0.5 % of set )
Slew rate
Operation mode
CC and CR
Selectable range (CC)
Range
H
0.10 A/
μ
s to 2.40 A/
μ
s
0.05 A/
μ
to 1.20 A/
μ
s
M
0.10 A/
μ
s to 0.24 A/
μ
s
0.05 A/
μ
to 0.12 A/
μ
s
L
24 mA/
μ
s
*1
12 mA/
μ
s
*1
Selectable range (CR)
Range
H
0.10 A/
μ
s to 0.24 A/
μ
s
0.05 A/
μ
to 0.12 A/
μ
s
M
24 mA/
μ
s
*1
12 mA/
μ
s
*1
L
2.4 mA/
μ
s
*1
1.2 mA/
μ
s
*1
Resolution
0.01 A/
μ
s
Accuracy of setting
*2
±(10 % of set + 5
μ
s)
Soft start
Operation mode
CC
Selectable time range
0.1, 1, 3, 10, 30, 100, or 300 ms
Time accuracy
±(30 % of set +100
μ
s)
Sequence function
Sequence
Operation mode
CC and CR
Maximum number of steps
255
Step execution time
1 ms to 9 999 s
Number of loops
1 to 9999 (9999 is in
fi
nite loop)
Содержание PLZ-30F
Страница 32: ...2 18 Installation and Preparation PLZ U ...
Страница 58: ...4 14 Basic Operation PLZ U ...
Страница 144: ...6 52 Remote Control PLZ U ...
Страница 145: ...PLZ U Maintenance 7 1 Chapter 7 Maintenance This chapter explains the PLZ U maintenance 7 7 ...
Страница 186: ...A 26 Appendix PLZ U ...
Страница 190: ...I 4 Index PLZ U ...
Страница 191: ......