Handling Overheat Alarms
When the overheat protection function of this product is activated, the internal phase circuits
are opened, shutting off the current. If the PCR CONTROL terminal function is used, the AC
power supply output can also be turned off when the overheat protection function is activated.
The detailed operation is described below.
Overcurrent (when the PCR CONTROL terminal function can be
used)
The overheat protection function is activated, and the AC power supply output is turned
off. The LIN OVERHEAT status signal is transmitted from the STATUS OUTPUT terminal.
Overcurrent (when the PCR CONTROL terminal function cannot be
used)
• When the PCR CONTROL terminal is not connected to the AC power supplies or the
connection is incomplete
In this situation, the AC power supply output will not be turned off even when the product’s
overheat protection is activated. However, the LIN OVERHEAT status signal will be trans-
mitted from the STATUS OUTPUT terminal.
Step
Handling
1
Leave the product’s POWER switch turned on. This will keep the fan running for
cooling.
2
After cooling the product adequately, turn on the POWER switch, and investigate
the cause of the overcurrent.
See
Step
Handling
1
To secure safety, when the ALARM indicator on the front panel turns on, turn off the
AC power supply output.
2
Leave the product’s POWER switch turned on. This will keep the fan running for
cooling.
3
After cooling the product adequately, turn on the POWER switch, and investigate
the cause of the overcurrent.