16
LIN-JF
Description of Parts
LIN3020JF
LINE IMPEDANCE NETWORK
LIN3020JF
POWER
ALARM
IMPEDANCE SELECT
REMOTE
1
2
3
4
5
6
7
8
9
10
11
㻝 㻞 㻟 㻠 㻡 㻢 㻣 㻤 㻥 㻝㻜
㻝 㻞 㻟 㻠 㻡 㻢 㻣 㻤 㻥 㻝㻜
㻺 㼃
㻺 㼂
㻺 㼁
䠣
䠪
䠳
䠲
䠱
䠪
䠨
䠣
䠪
䠳
䠪
䠲
䠪
䠱
CONTROL INPUT
STATUS OUTPUT
PCR
CONTROL
USB
VOLTAGE SENSING OUTPUT
LIN3020JF
WEIGHT APPROX 98kg
AC INPUT
100-240V
50 60Hz 150VA MAX
OUTPUT
PHASE VOLTAGE AC300V
LINE VOLTAGE AC500V 20A
INPUT
PHASE VOLTAGE AC300V
LINE VOLTAGE AC500V
20A MAX
12
13
14
15
16
17
18
19
21
20
22
No.
Name
Function
1
ALARM indicator
Lights when the internal overheat alarm occurs
2
REMOTE
Remote control switch (illuminated type)
3
BYPASS
Impedance bypass switch (illuminated type)
4
Z3
Z3 impedance switch (illuminated type)
5
Z2
Z2 impedance switch (illuminated type)
6
Z1
Z1 impedance switch (illuminated type)
7
Air inlet
Air inlet for internal cooling
8
Power indicator
Lights when the POWER switch is turned on
9
POWER switch
Power switch for the control power supply
10
Caster
Caster with a lock
11
Rack mount bracket
L-shaped bracket for mounting the product on a rack
12
Air outlet
Air outlet for internal cooling
13
CONTROL INPUT
Contact signal control input terminal
14
STATUS OUTPUT
Status output terminal
15
USB
Remote control USB port
16
PCR CONTROL
AC power supply control terminal
17
AC INPUT
Control power supply input terminal
18
Caster
Caster (without a lock)
19
OUTPUT
Output terminal block: G • N • W • N • V • N • U
20
INPUT
Input terminal block: G • N • W • V • U
21
VOLTAGE SENSING OUTPUT
Sensing terminal
22
Base hold angle
L-shaped bracket for fixing the product to the installation location