62
LIN-JF
Appendix A
Troubleshooting
This section introduces troubleshooting measures. Check whether any of the items listed
below apply to your case. If following the remedy does not solve your problem, contact your
Kikusui agent or distributor.
Symptom
Inspection
Remedy
Voltage is not
applied to the EUT.
The product’s POWER switch
is turned off.
• Turn on the POWER switch.
The AC power supply output is
turned off.
• Turn on the AC power supply
output.
—
The impedance is not
selected.
• The impedance switches are
not interlocked. Therefore,
turn off all switches first, and
then press the appropriate
switch.
The EXPAND terminals of the
LIN1020JF and OP01-
LIN1020JF are not connected
with an OP01 control cable.
• Connect the EXPAND termi-
nals of the LIN1020JF and
OP01-LIN1020JF with an
OP01 control cable.
Impedance cannot
be selected from the
front panel.
The product’s remote control
switch is turned on (the button
is pressed in).
• Turn off the product’s remote
control switch (release the
button).
The ALARM indica-
tor is lit.
The product’s ALARM indica-
tor is lit.
• The temperature inside the
product is too high. Allow the
product to cool down ade-
quately.
• Turn off the AC power supply
output.
Remote control
does not work.
The illumination area of the
REMOTE switch on the front
panel is turned off.
• Turn on the REMOTE switch
on the front panel.
The illumination area of the
REMOTE switch on the front
panel is turned on.
• Enable the remote signal.
• The product switches to
remote control mode when
the REMOTE switch is on and
the remote signal is being
received.
The impedance
error is large.
The AC power supply sensing
terminal is not connected or
has become disconnected.
• Connect the AC power sup-
ply sensing terminal securely.
See