48
LIN-JF
6
Operation
This chapter describes how to turn on the product, how to select the impedance, and how to
handle alarms.
Powering On
Turning on the POWER switch
1
Turn on the POWER switch of this product.
The power indicator turns on, and the cooling fan starts running.
Panel Operation
The panel control described below is for the LIN1020JF and LIN3020JF. The OP01-
LIN1020JF is used in combination with the LIN1020JF and is controlled from the LIN1020JF
panel. The OP01-LIN1020JF panel is for display only. It shows information according to the
operations performed on the LIN1020JF panel.
Selecting the impedance
There are impedance (IMPEDANCE SELECT) switches for Z1, Z2, Z3, and BYPASS. Each
switch is an independent bi-stable push switch. The switch is on when the button is pressed
in (illumination area is turned on) and off when the button is not (illumination area is turned
off). The button toggles between on and off each time you press it.
The switches are not interlocked. As such, if multiple switches are on at the same time, all the
selected circuits will be connected in parallel.
If all switches are off, no impedance is selected, and the N-phase circuit is open.
1
Turn off the AC power supply output.
2
Turn off the REMOTE switch on the front panel.
Set the switch so that the button is not pressed in. The illumination area of the
REMOTE switch will turn off, and panel control will be enabled.
3
Turn off all impedance (IMPEDANCE SELECT) switches on the front
panel.
Press one of the Z1, Z2, Z3, and BYPASS switches.
The illumination area of the selected switch will turn on.
4
To select another impedance, press the impedance switch that you want
to turn on and then the switch you want to turn off.