Connecting the Control Terminals
Connecting the PCR CONTROL terminal
The PCR CONTROL terminal is for controlling the AC power supplies. A signal is transmitted
when the overheat protection of this product is activated and turns off the AC power supply
output. Use the supplied exclusive cable for connecting this terminal.
If you want to use this product with the DSI series dip simulator in the test system, connect
the DSI series to the AC power supplies first, and connect this product last. For details, see
the operation manual for the DSI series.
Installing the supplied control boards into the AC power supplies
1
Check that the POWER switches of the AC power supplies are turned off
( ).
In addition, shut down the power supply from the switchboard.
2
Touch a grounded metal object (for example, the metal parts of the rear
panel) to discharge any static electricity from your body.
3
Remove the screws that are holding the SLOT 3 cover in place on the
rear panel, and remove the cover from the panel.
Keep the cover in a safe place. The screws that you removed will be used in step 6.
4
Flip the control board so that the side with the components is facing
down, and hold the panel area of the board.
5
Insert the board all the way into the slot so that the connector is firmly
inserted into the slot.
6
Use the screws that you removed earlier to fix the control board in place
in the panel.
LIN1020JF
LIN3020JF
CAUTION
Do not touch the circuit board area of the control board. Static electricity may damage
the circuit.