40 Remote Control
KDS6-0.2TR
OUTPut
Turns output on and off or inquires about the present setting.
Program message
•
Syntax
Command message:
OUTPut <{ON|OFF|1|0}>
OUTP <{ON|OFF|1|0}>
Query message:
OUTPut?
OUTP?
•
Program data
(Example) To set to turn output on:
OUTP 1
Response message
In response to
OUT?
, the present setting is returned as a character (1 or 0).
(Example) To turn output on:
1
To turn output off:
0
Output on/off setting
Data format
Character
1: ON (Output on)
0: OFF (Output off)
Initial value
0: OFF (Output off)
* The setting is reset to 0 when the power is turned off.