background image

Design Collection - Itoki Table  

Assembly Instructions

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

3

Figure 3

1/4-20 x 1”

Flat Hd

M6x20mm

Socket Hd

Figure 4

5. Position one of the leg assemblies 

over the threaded inserts in the 

top and loosely attach the leg 

to the surface with the provided 

hardware (Figure 3).

                                               

6. Attach one end of the cross 

brace  to the connector casting/

leg assembly using the hardware 

provided.  After all three of these 

bolts are started, tighten the 

hardware (Figure 4).

Содержание Design Itoki DD

Страница 1: ...Qty 4 M8 x 25mm Flat Hd cap screw w patch Qty 4 1 4 20 x 1 Flat Hd cap screw w patch Qty 8 M8 x 35mm Button Hd cap screw w patch Qty 4 M8 x 16mm Button Hd cap screw w patch Qty 8 M6 x 20mm Socket Hd c...

Страница 2: ...t in assembly failure and personal injury Figure 1 Figure 2 M8x25mm button Hd w Patch M8x16mm button Hd glide M8x25mm Flat Hd w Patch 3 Loosely assemble one leg con nector casting to one leg using two...

Страница 3: ...erly or to secure parts may result in assembly failure and personal injury 3 Figure 3 1 4 20 x 1 Flat Hd M6x20mm Socket Hd Figure 4 5 Position one of the leg assemblies over the threaded inserts in th...

Страница 4: ...o secure parts may result in assembly failure and personal injury Figure 5 7 Proceed in this manner with the other three legs and connector cast ings attaching each assembly to the cross brace and to...

Страница 5: ...leg stringer tube Qty 1 Worksurface stringer bar Qty 2 Table leg Y connector Qty 2 Leveling glide Qty 4 M8 x 25mm Flat Hd cap screw Qty 2 1 4 20 x 1 Flat Hd cap screw w patch Qty 4 1 4 20 x 1 Button...

Страница 6: ...n assembly failure and personal injury M8x25mm Flat Hd w patch Glides M8x25mm Flat Hd M8x35mm Button Hd Figure 6 Figure 7 3 Attach each Y shaped connector casting to two legs The connector should be s...

Страница 7: ...and must be checked periodically after assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 7 M8x16mm Button Hd 6 Turn the assembly over so the...

Страница 8: ...securely and must be checked periodically after assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 1 4 20 x 1 1 2 Flat Hd 1 4 20 x 1 1 2 Button...

Отзывы: