Result Analysis
2
Keysight X8712A IoT Device Battery Life Optimization Solution User’s Guide
45
The Calculation table contains several columns in colors that corresponds to the
front panel of the N6705C. The table below contains the details of each column
with its priority are arranged from highest to lowest (top to bottom).
Name
Label
Color
Definition
Ch 2 Pwr Det
DUT TX
Light
Green
Synchronous comes from X8712AD, assign as DUT’s TX
events with the highest priority.
Ch 2 Pwr Det
Pair TX
Dark
Green
Synchronous comes from X8712AD, assign as Pairing TX
or DUT RX events with second highest priority.
Ch 3 - XXX
Event 1
Blue
XXX could be in VM, AM or 2-QPS mode from selection,
synchronous from Channel 3. Default: VM
Ch 4 - XXX
Event 2
Purple
XXX could be in VM, AM or 2-QPS mode from selection,
synchronous from Channel 4. Default: VM
Avg Ch1 - Battery
Region 1
Pink
Zones are evenly distributed from minimum to maximum
of average channel 1 based on number of
set.
Avg Ch1 - Battery
Region 2
Dark
Yellow
Same as Region 1 with a lower priority
Avg Ch1 - Battery
Region 3
Brown
Same as Region 1 with the lowest priority
NOTE
When there are two events in the same zone, the software will prioritize the
events listed towards the left of the Calculation Source table. The software will
not take in consideration of the disabled channels as part of the
.