2
Result Analysis
48
Keysight X8712A IoT Device Battery Life Optimization Solution User’s Guide
Results
The following results are calculated based on the area set between the two line
markers in the main chart. See
to learn more about the main chart’s
functionalities.
You can view several of these results in the four charts available in
.
Results
Description
Time Consumed
The time taken for each occupied event under the cycle time.
Charge Consumed
Sorts synchronous physical or current events from
within cycle time.
Synchronous charge is defined as the mapping of the same time position
current in Channel 1 and integrating them as charge by event. The sum of all
charges by events will equal to Total Charge.
Charge by Event = Synchronous charge by events (Ah) / Total Charge (Ah)
within cycle time * 100%
Max Current
Maximum current recorded between the two line markers.
Avg Current
Average current recorded between the two line markers.
Avg current = Total Charge (Ah) / Cycle time (h).
Cycle Time
The time taken between the two line markers set in the main chart.