74
Keysight N5991 SATA Test Automation Software Platform User Guide
5
Receiver Tests
Data Generator
• Differential Voltage: The calibrated inner eye height at TP2.
• Random Jitter (RJ): The amount of calibrated RJ added to the signal.
• SJ Frequency: The frequency of the calibrated SJ added to the signal.
• Sinusoidal Jitter (SJ): The amount of calibrated SJ added to the signal.
• SSC Deviation: Maximum amount of deviation from the nominal data
rate due to down-spread SSC modulation.
• SSC Frequency: The frequency of the SSC modulation.
Used Calibrations
• Random Jitter Calibration
• Sinusoidal Jitter Calibration
• Differential Voltage Calibration