Installation Note N5242-90003 33
Description of the Upgrade
Installation Procedure for the Upgrade
Step 16. Reinstall the Front Panel Assembly and Front Panel Jumpers
Refer to
for this step of the procedure. New parts are listed in
1.
Make sure all of the hex nuts on the front-panel cable connectors have
been tightened using a 5/16-in torque wrench set to 21-in lbs.
2.
Reconnect the ribbon cable (item
③
) to the A1 front panel interface board.
3.
Slide the front panel over the front-panel connectors.
4.
With a T-10 TORX driver, reinstall the 12 screws (item
➁
) in the sides of
the frame.
5.
Reinstall the semirigid jumpers (item
①
) on the front panel, and tighten
each of the connectors to 10-in lbs.
Figure 19
Front Panel Assembly Reinstallation
Before installing the front panel assembly onto the analyzer, lift and
support the front of the analyzer chassis.