20 Keysight E8363B/C and E8364B/C Installation Note
General Information
Installation Procedure for the Upgrade Kit
1-
Analyzers WITH Options 014 AND 081
Refer to
for the following procedure. The new parts are
listed in
1.
Install the following cables in the order listed:
—
Ribbon cable
①
8121-0819A36 step attenuator to A16 motherboard
(P1 SRC ATT)
—
Ribbon cable
8121-0119A37 step attenuator to A16 motherboard
(P2 SRC ATT)
—
W52E8364-20056A22 switch splitter to A37 step attenuator
—
W51E8364-20055A22 switch splitter to A36 step attenuator
—
W71E8364-20015REFERENCE 2 RCVR R2 IN to A29 channel R2
mixer
—
W99E8364-20154A45 reference switch to A28 channel R1 mixer
—
W56E8364-20168A39 bias tee to A26 test port 2 coupler
—
W55E8364-20167A38 bias tee to A25 test port 1 coupler
—
W68E8364-20044A26 test port 2 coupler to PORT 2 CPLR ARM
—
W82E8364-20054A37 step attenuator to PORT 2 SOURCE OUT
—
W84E8364-20040PORT 2 CPLR THRU to A39 bias tee
—
W67E8364-20043A25 test port 1 coupler to PORT 1 CPLR ARM
—
W81E8364-20053A36 step attenuator to PORT 1 SOURCE OUT
—
W83E8364-20039PORT 1 CPLR THRU to A38 bias tee
2.
Route the bias tee control cables through the cable clamp, (item
③
), to
the rear of the analyzer for connection to the A16 motherboard later.
3.
Reinstall the semirigid cables, (item
④
), to the detectors.