![KEYLESS KE-350 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/keyless/ke-350/ke-350_installation-and-operation-manual_1960631007.webp)
KE-350 Installation and Operations Manual
The Installation Procedure
Required Tools
You will need the following tools:
1. Medium sized, Phillips head screwdriver
2. 1/8” standard screwdriver
3. Drill
4. 1” (25mm) drill bit
5. 1/2” (16mm) drill bit
6. 5/32” (4mm) drill bit (For 12-Pad 3x4)
7. 3/16” (6mm) drill bit (For Thinline 2x6)
Prepare the Keypad for Installation
There are different procedures for the two Keypad configurations: 12-Pad 3x4 and
Thinline 2x6. Templates for mounting the Keypads are located in Appendix D.
Thinline 2x6
The Thinline 2x6 is designed for mullion mount applications. It can also be mounted on
a wall, pedestal or any flat surface of at least 1 ¾” by 7”. The composition of the
mounting surface will determine the fastening method required:
1. Select a flat surface (1 ¾ ” by 7”) near the door where you wish to install the keypad.
2. Using the Thinline template (located in Appendix D), mark location of holes “A”,” B”
and “C”.
3. Drill the large hole marked “A” using a 1” (25mm) drill bit.
4. Place the connector on the back of the keypad in the large hole to verify that the
keypad mounting holes are aligned with marked holes “B” and “C”. Make
adjustments if necessary.
5. Drill clearance holes “B” and “C” in accordance with fastening method used.
6. Do NOT mount the keypad at this time.
12-Pad 3x4
The 3x4 keypad is designed to mount to a single gang switchbox or on a wall, pedestal
or any flat surface of at least 3 ½ by 5 ¼”. The composition of the mounting surface will
determine the fastening method required:
1. Select a flat surface (3 ½” by 5 ¼”) near the door where you wish to install the
keypad.
2. Using the 12-Pad 3x4 template (located in Appendix D), mark location of holes “A”,
“B” and “C”.
3. Drill the large hole marked “A” using a 1” (25mm) drill bit.
4. Place the connector on the back of the keypad in the large hole to verify that the
keypad mounting holes are aligned with marked holes “B” and “C”. Make
adjustments if necessary.
5. Drill clearance holes “B” and “C” in accordance with fastening method used. Be
careful when drilling hole “C” because of its’ proximity to hole “A”.
6. Do NOT mount the keypad at this time.
4
Содержание KE-350
Страница 1: ...Installation and Operations Manual KE 350 Keyless Entry Access Control System...
Страница 26: ...KE 350 Installation and Operations Manual Appendix A Typical Wiring Diagrams Figure A 23...
Страница 27: ...KE 350 Installation and Operations Manual Typical Wiring Diagrams Figure B 24...