KE-350 Installation and Operations Manual
Introduction
Overview
The KE-350 is a powerful yet easy to use single door, stand-alone access control system
with audit trail capabilities. The KE-350 can accommodate up to 500 individual Users, each
of which is assigned to one of 16 programmable User Groups. Additional features include a
32-day holiday schedule, manual or timed latching capabilities, optional use of Duress
Codes and the ability to automatically adjust Daylight Savings Time.
The KE-350 contains a 24-hour nonvolatile real time clock providing valid computations
through the year 2100. Fully Y2K compliant, the KE-350’s time clock enables access
control management through individual time zones tied to each User Group. The KE-350’s
time clock is also used to provide a time/date stamp for up to 750 transactions, which are
logged in the KE-350’s buffered audit trail. These transactions can easily be retrieved from
a parallel printer connected directly to the KE-350 control module.
Input Requirements
The KE-350 accepts 12 to 24 volts AC/DC. An optional battery charging module and
rechargeable Gel Cells are available to keep the system operational for up to 24 hours
during a power interruption.
Output Capabilities
Three SPDT dry contact relays offer the following:
Main Relay – The main relay is intended to activate either a Fail-Safe or a Fail Secure (Non
Fail-Safe) electronic locking device. It may also be configured as a dry contact relay output
to control a gate operator or garage door opener. The main relay is adjustable from 1 to 99
seconds with optional timed or manual latching.
2
nd
Relay – Can be programmed for one of the following options:
1. External Alarm System – Shunt or Enable/Disable an existing alarm
2. Internal Alarm System – Detect Break-in, Door-ajar, Duress and Tamper
3. Auxiliary Output – Manual Control or Timed Output (1 to 99 seconds)
3
rd
Relay – Can be programmed for one of the following options:
1. Doorbell – Press # at the Keypad to trigger a 1 second output for a doorbell (not
included)
2. CCTV or Light Controller – First key press triggers a Timed Output (1 to 99 seconds)
3. Auxiliary Output – Manual Control or Timed Output (1 to 99 seconds)