![KEYLESS KE-350 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/keyless/ke-350/ke-350_installation-and-operation-manual_1960631012.webp)
KE-350 Installation and Operations Manual
2
nd
RELAY: The KE-350’s 2
nd
Relay can be configured (page 14) as one of the following:
1. Controlling an External Alarm – The 2
nd
Relay can be configured to either
enable/disable or shunt an existing alarm system for 01 to 99 seconds.
2. Controlling Internal Alarm Features – The 2
nd
Relay can be used to monitor and
report events such as duress, break-in, door ajar and tamper. In order to detect
these occurrences, you will need to install a door monitor switch or latch monitor
switch. (See Install Other Switches section – page 6)
3. Controlling an Auxiliary Device – By default, the 2
nd
Relay is configured to provide
a 5 second momentary output. The 2
nd
Relay can be programmed to provide a
momentary output for 01 to 99 seconds or a manual ON/OFF output. The 2
nd
Relay is activated by entering “3#” following entry of an authorized User Code.
Entering “2#” following entry of an authorized code will deactivate the 2
nd
Relay.
3
rd
RELAY: The KE-350’s 3
rd
Relay can be configured (page 15) as one of the following:
1. Activate a Doorbell – The 3
rd
Relay can be used trigger a 1 second output to
activate a doorbell (not included with the KE-350). If the 3
rd
Relay is programmed
for a doorbell, simply entering “#” will activate the relay.
Note:
☞
Do not precede the “#” with any other keystrokes.
2. Controller for a Closed Circuit TV (CCTV) or External Light – By default, the 3
rd
Relay is configured to activate at the first touch of the Keypad and remain ON for
a 30 second time interval after the last keypad touch. This time interval can be
adjusted from 01 to 99 seconds.
3. Controlling an Auxiliary Device – The 3
rd
Relay can be configured to control an
auxiliary device of your choice. In this case the 3
rd
Relay can provide a
momentary output for 01 to 99 seconds or a manual ON/OFF output. The 3
rd
Relay is activated by entering “5#” following entry of an authorized User Code.
Entering “4#” following entry of an authorized code will deactivate the 3
rd
Relay.
AUTOMATIC LINE FEED (ALF): When connecting a parallel printer to the KE-350, most
printers require an automatic line feed to advance the printer paper to the next line. In
other cases, some printers have a built-in command to automatically provide this line
feed. If necessary, the printer line feed can be set ON or OFF. See System Setup
(page 15).
DAYLIGHT SAVINGS TIME (DST): By default, the KE-350 is configured to automatically
adjust the time clock twice each year for daylight savings time. The KE-350 makes the
adjustment at 2 a.m. In areas where this adjustment is not necessary, this option can be
turned off. To adjust the setting for automatic Daylight Savings Time adjustment,
proceed to System Setup (page 15).