![KEYLESS KE-350 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/keyless/ke-350/ke-350_installation-and-operation-manual_1960631015.webp)
KE-350 Installation and Operations Manual
Programming Individual Users (continued)
Keypad Status after Step Completion
Deleting a User by User ID
a) To delete a user by User ID, enter 3 #
b) Enter the User ID to be deleted (1 - 499),
followed by #
c) To delete an additional User, return to step b
d) If no more Users are to be deleted, enter
✼
✼
and return to Step 3
Deleting a User by User Code
a) To delete a user by User Code, enter 4 #
b) Enter the User Code to be deleted,
followed by #
c) To delete an additional User, return to step b
d) If no more Users are to be deleted, enter
✼
✼
and return to Step 3
Programming a Temporary User
a) To program a Temporary User, enter 5 #
b) Enter a Temporary User Code (3 to 8 digits),
followed by #
c) Enter the number of Hours of Authorized
Entry (01-99), followed by #
d) Return to Step 3
Deleting the Temporary User
a) To delete an active Temporary User
(before it expires), enter 6#
b) Return to Step 3
4.
To print Individual User(s)
a) Enter 9 #
b) To print a specific User, enter the User ID
Step
;
Beep
Red LED
Green LED
a)
Double Slow Flash Slow Flash
b)
Triple
Slow Flash Slow Flash
Step
;
Beep
Red LED Green LED
a)
Double Slow Flash Slow Flash
b)
Triple
Slow Flash Slow Flash
Step
;
Beep
Red LED Green LED
a)
Double Slow Flash Slow Flash
b)
Double Slow Flash Slow Flash
c)
Triple Slow
Flash Solid
Step
;
Beep
Red LED Green LED
a)
Triple Slow
Flash Solid
Step
;
Beep
Red LED Green LED
a)
Double Slow Flash Slow Flash
b)
Triple Slow
Flash Solid
(1 – 499, 500 for Temporary), followed by #
-- or --
To print all Users, enter 0 0, followed by #
c) To print another User, return to a)
Notes on Printing Individual Users: For security reasons, the master code can not be printed.
5.
Enter
✼
✼
to complete programming sequence and reset the system to normal operation.
General Notes on Programming Individual Users: Once an authorized user completes steps 1 & 2 to open the
memory, any combination of adding, modifying, deleting Users or programming Temporary Users can be
performed without having to re-enter steps 1 & 2 each time. However, if more than 1 minute elapses between
each step during programming, the system will reset and you will have to start from step 1.
12
Содержание KE-350
Страница 1: ...Installation and Operations Manual KE 350 Keyless Entry Access Control System...
Страница 26: ...KE 350 Installation and Operations Manual Appendix A Typical Wiring Diagrams Figure A 23...
Страница 27: ...KE 350 Installation and Operations Manual Typical Wiring Diagrams Figure B 24...