![Key Automation 900CT-PAE Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/key-automation/900ct-pae/900ct-pae_instructions-and-warnings-for-installation-and-use_1960063025.webp)
25
EN
4.6 - Views
Views of red indicator LEDs on NC contacts, green indicator LEDs
on NO contacts turn on when activated (radar/open/close)
Pressing the M key displays the following in sequence:
The total number of cycles automatically performed, ex-
pressed in hundreds.
The partial number of cycles automatically performed, ex-
pressed in hundreds: this counter can be reset by holding
the OK button for two seconds until you hear a beep.
If display is switched off you press and hold the OK button (until you
hear a beep) other information can be displayed in real time:
Position of the door (in encoder counts).
The learnt run (in encoder counts).
The learned approach space at opening (in counts en-
coder).
The learned approach space at opening (in counts en-
coder).
4.7 – Errors
The following errors or warnings, if present, are displayed immediately after
the operation mode:
Please note: Errors 3, 8 and 12 do not allow the operation of the
equipment; for each command (radar or other) you will hear a double
“beep” and the door remains stationary.
Please note: Errors 6 and 9 can only occur during a learning opera-
tion.
If there any errors take place, the LED on the switch flashes, while in the
presence of error 04 (power outage), the LED on the switch flashes at a
lower frequency
E 01: Obstacle detected during closing. - The device operation
continues normally.
E 02: Obstacle detected during opening. - The device opera-
tion continues normally.
E 03:
Faulty encoder. - Device locks and attempts to resume
operation only after being reset or turned off.
E 04: No electric power. - The device continues its operation,
as set by parameter “F”.
E 05:
Dead battery. - The device continues its operation nor-
mally, as set by parameter “G”.
E 06: Learnt run over maximum limit. - Device attempts to
resume operation only after being reset or turned off.
E 07:
Learning of weight failure - Device attempts to resume
operation only after being reset or turned off.
E 08:
Motor polarity reversed or encoder channels inverted. -
Device locks and attempts to resume operation only after
being reset or turned off.
E 09: Relative weight over maximum limit. - Device attempts to
resume operation only after being reset or turned off.
E 10: Motor voltage is over maximum allowed. - Device at-
tempts to resume operation only after a new command.
Battery voltage only be displayed with parameter P=1
(in Volt).
Instant current (in 1/100 Ampere) if the door is moving.
The maximum current of the last movement when the door is
stopped.
Motor voltage (in Volt)
Current obstacle threshold (in 1/100 Ampere)
The codes of the last 16 errors are automatically visualized
with an interval of 1 second, numbered from 1 (the most recent)
to 16 (the least recent).
After 60 seconds of inactivity, the display returns to show the mode
of operation.
Pressing +, you can temporarily display the currently configured
weight class.
E 11: Power circuit overload protection occurred. Device at-
tempts to resume operation only after a new command.
E 12:
Error while reading or writing eeprom memory - Device
attempts to resume operation only after being reset or
turned off.
E 13:
Monitored device 1 test failed command FOTO
E 14:
Monitored device 2 test failed command FOTO
E 15:
Monitored device 1 test failed command FOTO RALL
E 16:
Monitored device 2 test failed command FOTO RALL
E 17:
Monitored device 1 test failed command STOP
E 18:
Monitored device 2 test failed command STOP
Example of errors signal:
The first 2 numbers indicate the chronology of the errors (from 01
to 16). The last 2 indicate the type of error (according to the table)
Last error
no electric power
Second to last error
dead battery
Third to last error
obstacle detected during closing
Fourth to last error
obstacle detected during opening
START
P2
+
P4
M
P3
-
P5
OK
AS
In the example in the figure, the error is
02
the last two indicates
05
dead battery.
Other error examples as follows: