ThE DIspLAy
The user control has one neon and one display to inform the user about the status. The display will show the status of the boiler.
The neon will show the status of the flame. If no flame is detected the neon is off. When the flame is detected the neon will be lit
permanently.
The display scrolls through a maximum of 3 messages under any operational condition as shown below.
Notes:
Boiler frost protection - boiler fires if temperature is below 5º C.
The temperatures shown below are for illustration purposes only. The measured temperatures will be shown on the boiler.
33 INITIAL LIghTINg . . . . CONT’D
NORMAL OPERATION
MESSAGE 1
MESSAGE 2
MESSAGE 3
Mode knob in standby position and no
heat demand
Standby mode
For hot water turn mode
knob clockwise
For central heating turn
mode knob clockwise twice
Mode knob in summer position and no
heat demand
Summer mode
For central heating turn
mode knob clockwise
Mode knob in winter position and no
heat demand
Winter mode
Timer or room stat off
Domestic hot water operation
Hot water
Temperature 64ºC
High efficiency
Central heating operation
Radiator Temp 80ºC
High efficiency
Pre-heat operation
Pre heat
Central heating
Temperature 59ºC
High efficiency
Boiler frost protection
Boiler frost protection
Temperature 5ºC
Pump overrun
Pump overrun
Fan post-purge
Fan post-purge
High efficiency
Note. High efficiency will not be shown for central heating operation if the central heating flow temperature knob is set to greater than 73ºC.
3G971
1
DIspLAy FUNCTIONs IN NORMAL OpERATION
NORMAL OPERATION
MESSAGE 1
MESSAGE 2
MESSAGE 3
Pre-heat knob moved to off position
Pre heat off
Pre-heat knob moved to on position
Pre heat on
DHW temperature knob moved
64ºC DHW temp
Hot water
temperature 64ºC
CH temperature knob moved
80ºC CH temp
Maximum radiator
temperature 80ºC
May not be achieved for
high flow rates in winter
Mode knob moved to standby position
Central heating off
Hot water off
Mode knob moved to summer position
Summer mode
Standby mode
Central heating off
Hot water on
Mode knob moved to winter position
Winter mode
Central heating on
Mode knob moved to reset position
Reset
Hot water on
3G9712
DIspLAy FUNCTIONs - sETTINgs ChANgED
IN
s
T
ALLA
TION
207895-2.indd 33
02/01/2013 09:38:33
Содержание Combi 30
Страница 2: ...2 Keston Combi Installation and Servicing...
Страница 65: ...65 Short list of parts Keston Combi Installation and Servicing...
Страница 66: ...Gas Safe Register ID Number...