5
Installation
5.1
Check the installation conditions
Observe the prerequisites regarding the installation location:
Take the building waterproofing version into account (white tank or bituminous membrane), see corresponding installation
examples.
Calculate the height or thickness of the floor slab, the maximum depth must not be exceeded. An extension section
(accessories, art. no. 83075 or 83073) may be required.
Check whether the system is installed in a floor with water load. For groundwater resistance of the system,
.
Check whether pipe separation in accordance with EN 12056-4 is present. Wastewater and rainwater must be discharged
separately. For wastewater which occurs below the backwater level, the connection must also be downstream of the
downpipe.
5.1.1
Installation example white tank (floor slab with waterproof concrete)
1 Pumpfix F
2 Extension section with central flange
for installation in waterproof con-
crete, art. no. 83075
a Floor covering
f Insulation
b Waterproofing
layer
g Blinding layer
c Screed
h Control unit
d Concrete floor
i Cable conduit
e Insulation
BWS* design
water level
5.1.2
Installation example bituminous membrane (floor slab with separating layer)
1 Pumpfix F
2 Seal set art. no. 83073: extension
section with flange and counter-
flange (for connection to an on-site
sealing sheet)
3 Extension section art. no. 83070
a Floor covering
f Protective con-
crete
b Screed
g Control unit
c Insulation
h Cable conduit
d Concrete floor
BWS* design
water level
e Waterproofing
layer
EN
010-843
Installation and operating instructions
23 / 96