127
9. Malfunctions and remedial measure faults
Faults
Causes
Elimination
The clearing capacity of the facility
is disappointing
- Solenoid valve defective.
- A backup occurs at the point of
discharge. The water conveyed
with the clear water syphon flows
back again.
Most of the above-mentioned faults
can lead to a reduction of the puri-
fication performance. In addition,
there may be all kinds of reasons
for inadequate drain values such as
insufficient entry of air.
- Discharge of larger amounts of
detergents or disinfectants or
other forbidden substances
(paints, solvents, etc.) into the
plant.
- Sludge disposal not performed.
- Faulty settings for the population
values.
- Plant has been separated from the
power grid for a longer period of
time.
- If during the manual operation of
the clear water extraction no di-
stinct opening noise can be
heard, please call the after-sales
service. The point of discharge
must be cleared again.
- In the interest of the environment,
you should contact your after-
sales service to achieve an impro-
vement of the drain values.
Содержание InnoClean PLUS EW 10
Страница 2: ...2 ...
Страница 40: ...12 CE Konformitätserklärung Leistungserklärung 40 ...
Страница 85: ...85 12 Certificat de conformité declaration de performance ...
Страница 130: ...12 Declaration of performance conformity 130 ...
Страница 175: ...175 12 Deklaracja zgodności ...
Страница 176: ...176 12 Deklaracja zgodności ...
Страница 220: ...220 12 Dichiarazione di conformità CE ...
Страница 221: ...221 12 Dichiarazione di conformità CE ...
Страница 265: ...265 12 Verklaring van conformiteit ...
Страница 266: ...266 12 Verklaring van conformiteit ...
Страница 273: ...273 Verrohrung Tuyauteries Pipework Rury Tubazioni Leidingen ...
Страница 274: ...Verrohrung Tuyauteries Pipework Rury Tubazioni Leidingen 274 France ...
Страница 275: ...Verrohrung Tuyauteries Pipework Rury Tubazioni Leidingen France Retour de boues ...