62
9. Technical data
General technical data
Housing dimensions (L x W x H) 180 x 200 x 70 mm
Weight of switch unit approx 1 kg
Permissible temperature range 0 bis 50 °C
Mains standby (ready for operation) 14 mA
Mains current in operation 35 mA
Protective class I
Type of protection switchgear IP 54
Type of protection probe IP 68
Electrical connections suitable for
all copper conductors 0,08 - 2,5 mm
Cable sheath diameter 5 - 9 mm
Supply
Operating voltage 230 V AC 1~
50 Hz ± 10% L / N
Mains connection Safety plug on the switch
unit with 1.4 m
connection cable
Pre-fuse required max. C 16 A (provide on
installation side),
all-pole main switch in
the supply cable
Inputs
Sensor input SonicControl sensor input
Outputs
Potential-free switch contact
• Changeover contact: centre
contact; make contact; break
contact
• max. 42 VAC / 0.5 A
Option: Signal generator
Connection possibility for an
(Article-no. 20162) external signal generator