![Kessel 917824 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/kessel/917824/917824_installation-operation-and-maintenance-instructions_1957911056.webp)
7. Errors and Malfunction
Incident display Fault Cause Remedy
Communication error Acoustic signal and flashing Faulty modem reception Step 1: Check basic reception
possibility;
Step 2: If no reception is possible
then a modem cannot be used;
if reception is basically possible,
replace the modem
7.3 General faults:
Recognised fault Fault Cause Remedy
Deviation between the Faulty function caused by - Faulty sensor installation - Tighten the cable a little and
grease layer depth in the faulty measurement
then tighten the screw
inspection window and the connection by hand
measured depth of grease - Positioning during - Take the type of separator
layer installation
into account
- Faulty initial initialisation - Re-calibration of the sensor
- Dirt deposited on the sensor - Check the position of the
sensor
- Set the type of grease
- Set the type of grease and
clean the sensor
56