1.4  Maintenance and cleaning 

 
In any event, the device must be kept clean and dusted regularly. 
If any moisture should be occur, before you wipe down the device you must ensure 
that the mains power is switched off. 
 
When  glass  components  become  dirty,  the best  way  to  clean  them  is  to  wipe  them 
gently with a lint-free cloth. 
 
To wipe oil stains or finger prints off the lens surface, moisten the lint free cloth with a 
mixture of ether and alcohol (70 / 30 ratio) and use this to clean the lens. 
 
You must be careful when handling ether and alcohol, as these are highly flammable 
substances.  You  must  therefore  keep  it  away  from  naked  flames  and  electrical 
devices which can be switched on and off, and only use it in well-ventilated rooms. 
 
However organic solutions of this type should not be used to clean other components 
of the device. This could lead to damage to the paint finish. To do this, it is sufficient 
to use a neutral cleaning product. 
 
You could also use the following cleaning products to clean the optical components: 

  Special cleaner for optical lenses 

  Special optical cleaning cloths 

  Bellows 

  Brush 

 
When  handled  correctly  and  checked  regularly,  the  microscope  should  give  many 
years of efficient service. 
 
Should repairs still be necessary, please contact your KERN dealer or our Technical 
Department. 
 
 

 

Содержание OZG 497

Страница 1: ...N Sohn GmbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Jewellery microscope stereo zoom KERN OZG 497...

Страница 2: ......

Страница 3: ...ssembly 9 5 Operation and functionality 11 5 1 Getting started 11 5 2 Adjust the interpupillary distance 11 5 3 Adjusting the magnification 11 5 4 Dioptre adjustment and focussing 12 5 5 Adjusting the...

Страница 4: ...ting to a mains power supply you must make sure that you are using the correct input voltage The information to select the correct power supply is located on the device on the rear of the stand base Y...

Страница 5: ...holder must not be rotated back too far If you do this there is a risk that the microscope could tip over When the microscope is not being used you should fit the objective cap and cover the microscop...

Страница 6: ...s these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organ...

Страница 7: ...OZG_497 BA e 1510 6 2 Nomenclature...

Страница 8: ...7 OZG_497 BA e 1510 Rear view...

Страница 9: ...On both sides Packaging dimensions WxDxH 600x480x400 mm Product dimensions WxDxH 340x235x580 mm Gross weight 14 7 kg Net weight 11 5 kg Standard configuration Model KERN Tube Eyepiece Field of view mm...

Страница 10: ...the microscope To do this there is a screw connection both on the stand as well as the bulb housing of the front light After that you should bring the front light into the correct position Now the goo...

Страница 11: ...scopes can be fitted to the eyepieces see section 5 6 You can fit a C mount adapter to the appropriate connection point on the top of the microscope head This enables you to fit and use digital camera...

Страница 12: ...illary distances So each time a different person uses the microscope the gap between the two eyepieces must be re adjusted While you are looking through the eyepieces use one hand to hold the righthan...

Страница 13: ...ough the right eyepiece with the right eye and bring the object into focus by using the focus control dials 5 Now set the largest possible zoom factor 6 Once again still only looking through the right...

Страница 14: ...unintentionally In this way you can avoid possible damage which could occur if the objective lens and the object being observed should collide Tilt function The stand of the microscope has a tilt func...

Страница 15: ...ied by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved W...

Страница 16: ...n be used to switch it on and off It is not connected to the dimmer wheel and does not have one of its own So the light intensity does not vary at all However the advantage of the front light is that...

Страница 17: ...ot suitable for C Mount cameras You firstly have to remove this adapter in order to attach an appropriate one In total there are three focusable adapters to choose from see figure below The difference...

Страница 18: ...doing this please make sure that all microscope components are firmly fixed The bulb which appears inside the open lamp housing can then be simply pulled out of its socket and replaced with a new bulb...

Страница 19: ...mm OZB A4119 HSWF 20x 14 5 mm OZB A4120 HWF 25x 11 7 mm OZB A4121 C Mount 1x OZB A4809 0 3x OZB A4810 0 5x OZB A4811 Dark field attachment Dark field attachment OZB A4601 Object clamp Object clamp ste...

Страница 20: ...sufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The interpupillary distance is not set correctly The magnifications of...

Страница 21: ...y materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Отзывы: