Before use 

 

1.1  General notes 

 
You must open the packaging carefully, to make sure that none of the accessories in 
the packaging fall on the floor and get broken. 
 
In  general,  microscopes  should  always  be  handled  carefully  because  they  are 
sensitive  precision  instruments.  When  using  or  transporting  the  microscope  it  is 
particularly  important  to  avoid  abrupt  movements,  as  this  may  damage  the  optical 
components. 
 
You  should  also  avoid  getting  dirt  or  finger  prints  on  the  lens  surface,  because  in 
most cases this will reduce image clarity. 
 
To maintain the performance of the microscope, it must never be disassembled. So 
components  such  as  lenses  and  other  optical  elements  should  be  left  as  they  were 
before use. Also the electrical parts in the base of the device must not be tampered 
with, as in this area there is an additional risk of triggering an electric shock. 

 
 

1.2  Notes on the electrical system

 

 

 
Before connecting to a mains power supply, you must make sure that you are using 
the  correct  input  voltage.  The  information  to  select  the  correct  power  supply  is 
located  on  the  device,  on  the  rear  of  the  stand  base.  You  must  comply  with  this 
information.  If  you  do  not  comply  with  these  specifications,  then  fires  or  other 
damage to the device could occur. 
 
The main  switch must  also  be  switched off before  the mains  cable  is  connected.  In 
this way you will avoid triggering an electric shock. 
 
If  the  original  fuse  should  blow,  it  must  only  be  replaced  by  an  appropriate  fuse. 
Suitable replacement fuses are included with the delivery. 
 
When carrying out any procedures whereby you come into contact with the electrical 
system of the device, such as, for example, changing the bulb or fuse, only carry out 
these procedures when the power is disconnected. 
 
Under no circumstances should you touch the integrated halogen bulbs or housings 
either during operation or directly after use. These bulbs produce significant heat and 
therefore there is a risk that the user could be severely burnt. So before handling the 
bulbs, you must check that they have cooled down. 
 

 

Содержание OZG 497

Страница 1: ...N Sohn GmbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Jewellery microscope stereo zoom KERN OZG 497...

Страница 2: ......

Страница 3: ...ssembly 9 5 Operation and functionality 11 5 1 Getting started 11 5 2 Adjust the interpupillary distance 11 5 3 Adjusting the magnification 11 5 4 Dioptre adjustment and focussing 12 5 5 Adjusting the...

Страница 4: ...ting to a mains power supply you must make sure that you are using the correct input voltage The information to select the correct power supply is located on the device on the rear of the stand base Y...

Страница 5: ...holder must not be rotated back too far If you do this there is a risk that the microscope could tip over When the microscope is not being used you should fit the objective cap and cover the microscop...

Страница 6: ...s these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organ...

Страница 7: ...OZG_497 BA e 1510 6 2 Nomenclature...

Страница 8: ...7 OZG_497 BA e 1510 Rear view...

Страница 9: ...On both sides Packaging dimensions WxDxH 600x480x400 mm Product dimensions WxDxH 340x235x580 mm Gross weight 14 7 kg Net weight 11 5 kg Standard configuration Model KERN Tube Eyepiece Field of view mm...

Страница 10: ...the microscope To do this there is a screw connection both on the stand as well as the bulb housing of the front light After that you should bring the front light into the correct position Now the goo...

Страница 11: ...scopes can be fitted to the eyepieces see section 5 6 You can fit a C mount adapter to the appropriate connection point on the top of the microscope head This enables you to fit and use digital camera...

Страница 12: ...illary distances So each time a different person uses the microscope the gap between the two eyepieces must be re adjusted While you are looking through the eyepieces use one hand to hold the righthan...

Страница 13: ...ough the right eyepiece with the right eye and bring the object into focus by using the focus control dials 5 Now set the largest possible zoom factor 6 Once again still only looking through the right...

Страница 14: ...unintentionally In this way you can avoid possible damage which could occur if the objective lens and the object being observed should collide Tilt function The stand of the microscope has a tilt func...

Страница 15: ...ied by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved W...

Страница 16: ...n be used to switch it on and off It is not connected to the dimmer wheel and does not have one of its own So the light intensity does not vary at all However the advantage of the front light is that...

Страница 17: ...ot suitable for C Mount cameras You firstly have to remove this adapter in order to attach an appropriate one In total there are three focusable adapters to choose from see figure below The difference...

Страница 18: ...doing this please make sure that all microscope components are firmly fixed The bulb which appears inside the open lamp housing can then be simply pulled out of its socket and replaced with a new bulb...

Страница 19: ...mm OZB A4119 HSWF 20x 14 5 mm OZB A4120 HWF 25x 11 7 mm OZB A4121 C Mount 1x OZB A4809 0 3x OZB A4810 0 5x OZB A4811 Dark field attachment Dark field attachment OZB A4601 Object clamp Object clamp ste...

Страница 20: ...sufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The interpupillary distance is not set correctly The magnifications of...

Страница 21: ...y materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Отзывы: