B-8
ABC 040104
B.25
[SOUR:]LIST:CURRent:PROTect?
QUERY
LIST:CURR:PROT?
Syntax:
Short Form: LIST:CURR[:LEV]?
Long Form: LIST:CURRent[:LEVel]?
Return Value: <exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Returns current protection value (Amps) stored in indexed memory location selected by
LIST:IND.
Related Commands: LIST:IND. LIST:IND?, LIST:CURR. (See example, Figure B-4.)
B.26
[SOUR:]LIST:DWELl
COMMAND
LIST:DWEL
Syntax:
Short Form: LIST:DWEL <value> (0.01 to 300)
Long Form: LIST:DWELl <value> (0.01 to 300)
Description:
Determines the execution time duration during a programmed sequence for the memory loca-
tion selected by LIST:IND.
Sets time value (from 0.01 to 300) in seconds for memory location
selected by LIST:IND. A value of 0 means that this memory location will be skipped during the RUN
command (LOCal mode). The time value is stored in non-volatile memory and is retained when the
power supply is turned off. Related Commands: LIST:IND. LIST:IND?, LIST:DWEL?, LIST:SEQ. (See
example, Figure B-4.)
B.27
[SOUR:]LIST:DWELl?
QUERY
LIST:DWEL?
Syntax:
Short Form: LIST:DWEL?
Long Form: LIST:DWELl?
Return Value: <value> (0.01 to 300)
B.28
[SOUR:]LIST:INDex
COMMAND
LIST:IND
Syntax:
Short Form: LIST:IND <int_value> (from 1 to 40) Long Form: LIST:INDex <int_value> (from 1 to 40)
Description:
Selects one 40 memory locations for viewing or modification of parameter selected by subse-
quent LIST:CURR, LIST:CURR:PROT, LIST:VOLT, LIST:VOLT:PROT commands or queries.
The
index value (the selected memory location) is stored in non-volatile memory and is retained when the
power supply is turned off. Related Commands: LIST:IND?. (See example, Figure B-4.)
B.29
[SOUR:]LIST:INDex?
QUERY
LIST:IND?
Syntax:
Short Form: LIST:IND?
Long Form: LIST:INDex?
Return Value: <int_value> 1 to 40
Description:
Returns index value.
Identifies which one 40 memory locations has been selected for viewing or
modification by subsequent LIST:CURR, LIST:CURR:PROT, LIST:VOLT, LIST:VOLT:PROT commands
or queries. Related Commands: LIST:IND?. (See example, Figure B-4.)
B.30
[SOUR:]LIST:SEQuence:NEXT
COMMAND
LIST:SEQ:NEXT
Syntax:
Short Form: LIST:SEQ:NEXT <int_value> (0 to 40)
Long Form: LIST:SEQuence:NEXT <int_value> (0 to 40)
Description:
Determines the next memory location to be addressed during a programmed sequence.
Sets
sequence number (from 1 to 40) of next memory location to be addressed. Sequence number is set
for memory location selected by LIST:IND. Setting sequence number to 0 indicates the end of the pro-
gram chain, and the programmed sequence will stop. The sequence number is stored in non-volatile
memory and is retained when the power supply is turned off. Related Commands: LIST:IND.
LIST:IND?, LIST:SEQ?. (See example, Figure B-4.)
B.31
[SOUR:]LIST:SEQuence:NEXT?
QUERY
LIST:SEQ:NEXT?
Syntax:
Short Form: LIST:SEQ:NEXT? Long Form: LIST:SEQuence:NEXT?
Return Value: <int_value> (0 to 40)
Description:
Returns sequence number stored in memory location selected by LIST:IND.
Related Com-
mands: LIST:IND. LIST:IND?, LIST:SEQ. (See example, Figure B-4.)
Содержание ABC 10-10DM
Страница 2: ......
Страница 6: ......
Страница 14: ...viii ABC 040104 FIGURE 1 1 ABC SERIES POWER SUPPLY...
Страница 18: ...1 4 ABCOPR040104 FIGURE 1 1 ABC SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING...
Страница 19: ...ABCOPR040104 1 5 FIGURE 1 2 ABC POWER SUPPLY AND RA 71 RACK ADAPTER OUTLINE DRAWING...
Страница 20: ...1 6 ABCOPR040104 FIGURE 1 3 TWO ABC POWER SUPPLIES AND RA 72 RACK ADAPTER OUTLINE DRAWING...
Страница 24: ......
Страница 58: ......
Страница 64: ......
Страница 94: ......
Страница 96: ...FOLD HERE Please place stamp here KEPCO INC 131 38 SANFORD AVE FLUSHING NY 11352 USA CUT HERE...