
KEOFITT W9 USER MANUAL V.4
PAGE 25
1. Open the valve slowly and take the sample.
NB! In order to flush the valve seat before sampling you may choose
to let the first few seconds of flow go to drain.
2. Close the valve after the sample has been taken.
3. Clean the valve by flushing with steam, water or hot water.
If the process media is sticky, viscous or aggressive or for any other appropriate reason, do repeat a full
CIP cycle after sampling in case steam is not available and flushing with water prove insufficient.
WARNING
• When sampling at a high pressure and/or with a low viscosity process media it may flow rapidly
into the sample recipient. Therefore open the valve slowly. Special care must be taken with
pneumatically operated valves, as they open abruptly. If problematic, consider adjustable
actuators.
• Always remember to wear safety goggles when steaming, CIPping, taking samples or any other
operations of the sampling valve
Содержание W9
Страница 1: ...DON T GAMBLE WITH YOUR SAMPLE W9 SAMPLING VALVE User Manual ...
Страница 4: ...KEOFITT W9 USER MANUAL V 4 PAGE 4 ...
Страница 36: ...KEOFITT W9 USER MANUAL V 4 PAGE 36 12 5 Keofitt valve type Varivent 12 6 Keofitt valve type thread ...
Страница 44: ...KEOFITT W9 USER MANUAL V 4 PAGE 44 16 MEMBRANES 16 1 Silicone membrane art no 600051 ...
Страница 45: ...KEOFITT W9 USER MANUAL V 4 PAGE 45 16 2 Silicone membrane for Micro Port art no 600251 ...
Страница 46: ...KEOFITT W9 USER MANUAL V 4 PAGE 46 16 3 EPDM membrane art no 600052 ...
Страница 47: ...KEOFITT W9 USER MANUAL V 4 PAGE 47 16 4 EPDM membrane for Micro Port art no 600252 ...
Страница 48: ...KEOFITT W9 USER MANUAL V 4 PAGE 48 16 5 FFKM membrane art no 600053 ...
Страница 49: ...KEOFITT W9 USER MANUAL V 4 PAGE 49 16 6 PTFE membrane art no 850055 ...