KEOFITT W9 USER MANUAL V.4
PAGE 11
The company Novadan ApS, Kolding, Denmark has supplied the table below, as a preliminary indication
of which type of disinfectant to use:
Disinfectant
Microbes to inactivate
Halogenes
(Clorine)
Peroxides
(hydrogenperoxid &
peracetic acid)
Alcohol
(70%)
Gram-neg
bacteria
Salmonella
Campylobacter
E. Coli and others...
Gram-pos
bacteria
Listeria
Bacillus cereus
Clostridium and others...
Bacteria
spores
Bacillus cereus and others...
Bacteriophage
Yeast
Fungi
Virus
Legend:
Efficient
Limited effect
Little/No effect
NOTE!
The final choice of detergent, disinfectant and method lies with the user, supported by the
supplier of the CIP fluids and disinfectants, as it is very much dependant on individual concerns
and circumstances.
2.3 Sterilisation
Sterilisation is a high-level disinfection designed to render the valve free of all forms of viable
microorganisms (incl. bacterial spores) to a high level of certainty; the so-called Sterility Assurance Level
or SAL. A SAL value of 10-
6
means that the probability (or risk) of a single viable microorganism being
present on the valve interior afterwards is only 1 in 1,000,000 which is a generally accepted level for
calling an item sterile. Although the probability can be reduced to a very low number, it can never be
reduced to zero.
Sterility may in practise only be obtained by steaming. Disinfectants exist that in high concentrations
and for a prolonged exposure time will be able to inactivate all forms of microorganisms and render the
valve interior sterile with a high probability; these disinfectants are called chemical sterilants. However,
the application of chemical sterilants is most often problematic due to a) a required high concentration,
which causes an operator hazard and b) the several hours of exposure time.
NOTE!
Furthermore, sterilisation with a chemical sterilant may not convey the same sterility as-
surance as sterilisation with steam, because the germicidal and sporicidal kinetics are much less
investigated and documented for chemical sterilants compared to steam.
Содержание W9
Страница 1: ...DON T GAMBLE WITH YOUR SAMPLE W9 SAMPLING VALVE User Manual ...
Страница 4: ...KEOFITT W9 USER MANUAL V 4 PAGE 4 ...
Страница 36: ...KEOFITT W9 USER MANUAL V 4 PAGE 36 12 5 Keofitt valve type Varivent 12 6 Keofitt valve type thread ...
Страница 44: ...KEOFITT W9 USER MANUAL V 4 PAGE 44 16 MEMBRANES 16 1 Silicone membrane art no 600051 ...
Страница 45: ...KEOFITT W9 USER MANUAL V 4 PAGE 45 16 2 Silicone membrane for Micro Port art no 600251 ...
Страница 46: ...KEOFITT W9 USER MANUAL V 4 PAGE 46 16 3 EPDM membrane art no 600052 ...
Страница 47: ...KEOFITT W9 USER MANUAL V 4 PAGE 47 16 4 EPDM membrane for Micro Port art no 600252 ...
Страница 48: ...KEOFITT W9 USER MANUAL V 4 PAGE 48 16 5 FFKM membrane art no 600053 ...
Страница 49: ...KEOFITT W9 USER MANUAL V 4 PAGE 49 16 6 PTFE membrane art no 850055 ...