3. VALVE DESIGN AND FUNCTIONING
The Keofitt sampling valve is conceived to extract representative samples from a production process
at regular intervals during a batch without compromising the ongoing process. The valve is therefore
designed such that effective cleaning, disinfection/sterilisation and sampling can be carried out regularly
without disturbing the production process.
3.1 Valve body configurations
Valve bodies may be welded to the process equipment or connected by means of one of the standard
connector systems.
Welding configurations encompass the following options:
•
Tank welding, ø28 mm
•
Pipe welding, 1”
•
Pipe welding, NW25
•
In-line vertical
•
In-line horizontal
Connector configurations encompass the following options:
•
Varivent, ø50 mm
•
Varivent, ø68 mm
•
Clamp ½”
•
Clamp 1"; Clamp1", NA-connect, DIN/ASME
•
Clamp 2"; Clamp2", NA-connect, DIN/ASME
• Thread
•
DIN 11851
The inlet and outlet ports are available in the following configurations:
•
Hose Piece (Keofitt Quick Coupling)
•
Mini Tri-clamp
•
Thread M16x1.5
•
Welding ends (to weld steel tubing on)
All welding/connector options are available with Hose Piece ports. For the other port configurations
only some combinations are standard; but all non-standard combinations are likely to be available “On
request”.
All valve bodies with their various ports are machined in one piece of steel, thus avoiding all crevices and
fissures from screwed or welded parts.
For further information please consult www.keofitt.dk.
3.2 Valve surfaces and roughness certificate
All Keofitt valves are electro polished internally using a proprietary technique and each valve has its
individual certificate (Test Report) stating the results of 4 test measurements of the surface roughness in
each of the 2 ports, in the valve chamber and on the outer body surface with product contact.
For obvious reasons, the surface properties of the internal product contact areas of a sampling valve is
much more important from a hygiene perspective than any shiny outside surface appearance. Therefore,
Keofitt has developed a unique electrode configuration to assure during manufacturing that the internal
surfaces in particular are properly electro polished.
Содержание W9
Страница 1: ...DON T GAMBLE WITH YOUR SAMPLE W9 SAMPLING VALVE User Manual ...
Страница 4: ...KEOFITT W9 USER MANUAL V 4 PAGE 4 ...
Страница 36: ...KEOFITT W9 USER MANUAL V 4 PAGE 36 12 5 Keofitt valve type Varivent 12 6 Keofitt valve type thread ...
Страница 44: ...KEOFITT W9 USER MANUAL V 4 PAGE 44 16 MEMBRANES 16 1 Silicone membrane art no 600051 ...
Страница 45: ...KEOFITT W9 USER MANUAL V 4 PAGE 45 16 2 Silicone membrane for Micro Port art no 600251 ...
Страница 46: ...KEOFITT W9 USER MANUAL V 4 PAGE 46 16 3 EPDM membrane art no 600052 ...
Страница 47: ...KEOFITT W9 USER MANUAL V 4 PAGE 47 16 4 EPDM membrane for Micro Port art no 600252 ...
Страница 48: ...KEOFITT W9 USER MANUAL V 4 PAGE 48 16 5 FFKM membrane art no 600053 ...
Страница 49: ...KEOFITT W9 USER MANUAL V 4 PAGE 49 16 6 PTFE membrane art no 850055 ...