![Kenwood TK-5210 Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/kenwood/tk-5210/tk-5210_service-manual_191525059.webp)
TK-5210
(
G
)
59
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
9. DTMF
Deviation
*2
[Wide]
[Concentric SW]: A
1) Adj item: [W DTMF
Dev]
Adjust:
[***]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Wide)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
Write the value as
followings.
172 (Reference
value)
3.0kHz±50Hz
[Narrow]
[Concentric SW]: B
1) Adj item: [N DTMF
Dev]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Narrow)]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1.5kHz±50Hz
10. Single
Tone
Deviation
*2
[Wide]
[Concentric SW]: A
1) Adj item: [W Tone
Dev]
Adjust:
[***]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Wide)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
Write the value as
followings.
135 (Reference
value)
3.0kHz±50Hz
[Narrow]
[Concentric SW]: B
1) Adj item: [N Tone
Dev]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Narrow)]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1.5kHz±50Hz
11. MSK
Deviation
*2
[Wide]
[Concentric SW]: A
1) Adj item: [W MSK
Dev]
Adjust:
[***]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Wide)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
Write the value as
followings.
133 (Reference
value)
3.0kHz±50Hz
[Narrow]
[Concentric SW]: B
1) Adj item: [N MSK
Dev]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Narrow)]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1.5kHz±50Hz