TK-5210
(
G
)
57
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
3. Balance *2 1) Adj item: [Balance]
Adjust:
[***]
Deviation
meter
LPF: 3kHz
HPF: OFF
2) Adj item: [L]
→
[LC]
→
[C]
→
[CH]
→
[H]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [Balance]
Deviation
meter
LPF: 3kHz
HPF: OFF
2) Adj item: [Frequen-
cy]
[Low]
→
[Low’]
→
[Center]
→
[High’]
→
[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
Make the demodu-
lation waves into
square waves.
4. Mic
Sensitivity
1) Adj item: [Mic
Sense]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value
1) Adj item: [Mic Sen-
sitivity]
PTT: Press [Trans-
mit] button. Press
[OK] button to store
the adjustment
value.
Deviation
meter
Oscilloscope
AG
AF VTVM
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
Write the value as
followings.
48 (Reference
value)
Adjust AG input
to get a standard
MOD., 3.0kHz.
Mic sensitivity
check:
15mV±3.5mV
5. Max
Deviation
*2
[Narrow]
[Concentric SW]: B
1) Adj item: [N FM
Max Dev]
Adjust:
[***]
Deviation
meter
LPF: 15kHz
HPF: OFF
2) Adj item: [L]
→
[LC]
→
[C]
→
[CH]
→
[H]
PTT:
ON
Adjust:
[***]
Press [B] key to
store the adjust-
ment value.
1) Adj item: [Max
Deviation (Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
2) Adj item: [Frequen-
cy]
[Low]
→
[Low’]
→
[Center]
→
[High’]
→
[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
2.0kHz
(According to the
, –)
±15Hz
[Wide]
[Concentric SW]: A
1) Adj item: [W FM
Max Dev]
Adjust:
[***]
2) Adj item: [L]
→
[LC]
→
[C]
→
[CH]
→
[H]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [Max
Deviation (Wide)]
2) Adj item: [Frequen-
cy]
[Low]
→
[Low’]
→
[Center]
→
[High’]
→
[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
4.0kHz
Set it the ad-
justment value
obtained from the
[Max Deviation
Adjust [Narrow]]
adjustment of step
2).
±50Hz