TK-3202
25
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
7. DQT
1) Test CH: Center, Low, High
Power meter Panel
ANT
PC
KPG-87D Make the demodu-
balance
(3 points)
(M2)
lation wave into
adjustment
Deviation meter filter
Deviation
SP/MIC
square waves
• Wide 5k
LPF: 3kHz
meter
connector
HPF: OFF
Oscilloscope
PTT: ON
AG
AF VTVM
• Wide 4k
2) Test CH: Center
PTT: ON
• Narrow
3) Test CH: Center
PTT: ON
8. QT deviation 1) Test CH: Center, Low, High
0.85kHz
±
40Hz
adjustment
(3 points)
• Wide 5k
Deviation meter filter
LPF: 3kHz
HPF: OFF
PTT: ON
• Wide 4k
2) Test CH: Center
0.70kHz
±
40Hz
PTT: ON
• Narrow
3) Test CH: Center
0.45kHz
±
40Hz
PTT: ON
9. DQT
1) Test CH: Center, Low, High
0.75kHz
±
40Hz
deviation
(3 points)
adjustment
Deviation meter filter
• Wide 5k
LPF: 3kHz
HPF: OFF
PTT: ON
• Wide 4k
2) Test CH: Center
0.60kHz
±
40Hz
PTT: ON
• Narrow
3) Test CH: Center
0.35kHz
±
40Hz
PTT: ON
Receiver Section
1. BPF wave
1) Center frequency
SSG
Panel
ANT
PC
KPG-87D Adjust the wave-
adjustment
Spectrum analyzer setting
(M2)
form as shown to
Center f.: 455.10MHz
Spectrum
TX-RX
BPF
the Fig. 1 (page 27)
E
Span: 100MHz
analyzer
RBW: 100kHz
VBW: 30kHz
ATT: 10dB
2) High-edge frequency
Spectrum analyzer setting
Center f.: 469.90MHz
Span: 120MHz
3) Low-edge frequency
Spectrum analyzer setting
Center f.: 440.05MHz
Span: 80MHz
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method