TK-3202
26
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
E3
1) Center frequency
SSG
Panel
ANT
PC
KPG-87D Adjust the wave-
Spectrum analyzer setting
(M2)
form as shown to
Center f.: 415.10MHz
Spectrum
TX-RX
BPF
the Fig. 1 (page 27)
Span: 100MHz
analyzer
RBW: 100kHz
VBW: 30kHz
ATT: 10dB
2) High-edge frequency
Spectrum analyzer setting
Center f.: 429.90MHz
3) Low-edge frequency
Spectrum analyzer setting
Center f.: 400.10MHz
Span 80MHz
2. Sensitivity
1) Test CH: Low, Center, High
SSG
Panel
ANT
Check
20dB SINAD or more
check
SSG output: –114dBm (0.45
µ
V)
• Wide 5k
SSG MOD: 3.0kHz
DVM
SP/MIC
Oscilloscope
connector
• Wide 4k
2) Test CH: Low, Center, High
AF VTVM
SSG output: –114dBm (0.45
µ
V)
SSG MOD: 2.4kHz
• Narrow
3) Test CH: Center
SSG output: –112dBm (0.56
µ
V)
SSG MOD: 1.5kHz
3. SQL1
1) Test CH: Low, Center, High
PC
KPG-87D Write
Squelch open
(Threshold)
SSG output: –122dBm (0.18
µ
V)
(M2)
writing
SSG MOD: 3.0kHz
• Wide 5k
• Wide 4k
2) Test CH: Center
SSG output: –122dBm (0.18
µ
V)
SSG MOD: 2.4kHz
• Narrow
2) Test CH: Center
SSG output: –121dBm (0.2
µ
V)
SSG MOD: 1.5kHz
4. SQL9
1) Test CH: Low, Center, High
(Tight)
SSG output: –116dBm (0.35
µ
V)
writing
SSG MOD: 3.0kHz
• Wide 5k
• Wide 4k
2) Test CH: Center
SSG output: –116dBm (0.35
µ
V)
SSG MOD: 2.4kHz
• Narrow
2) Test CH: Center
SSG output: –115dBm (0.4
µ
V)
SSG MOD: 1.5kHz
5. BATT
1) BATT terminal voltage: 5.9V
SSG
Panel
ANT
Write
BATT terminal voltage: 5.9V
detection
writing
DVM
TX-RX
BATT
terminal