TK-3202
24
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
1. Setting
1) BATT terminal voltage: 7.5V
2) SSG sandard modulation
Wide 5k
MOD: 1kHz, DEV: 3kHz
Wide 4k
MOD: 1kHz, DEV: 2.4kHz
Narrow
MOD: 1kHz, DEV: 1.5kHz
2. VCO lock
1) CH: High
Power meter Panel
ANT
TX-RX
TC2
3.6V
±
0.1V
voltage
• RX
DVM
TX-RX
CV
2) CH: Low
Check
0.6V or more
• TX
3) CH: High
TX-RX
TC1
3.2V
E
±
0.1V
PTT: ON
3.0V
E3
4) CH: Low
Check
0.6V or more
PTT: ON
1. Frequency
1) CH: High
F. counter Panel
ANT
TX-RX
VR1
High frequency
±
50Hz
adjustment
PTT: ON
2. High power
1) Test CH: Low, Low’, Center,
Power meter
PC
KPG-87D 4.0W
±
0.1W
adjustment
High’, High (5 points)
Ammeter
(M2)
2.0A or less
BATT terminal voltage: 7.5V
PTT: ON
3. Low power
1) Test CH: Low, Low’, Center,
1.0W
±
0.1W
adjustment
High’, High (5 points)
1.0A or less
BATT terminal voltage: 7.5V
PTT: ON
4. Maximum
1) Test CH: Center, Low, High
Power meter Panel
ANT
4.2kHz
±
80Hz
deviation
(3 points)
(According to the
adjustment
AG: 1kHz/150mV
Deviation
SP/MIC
, –)
• Wide 5k
Deviation meter filter
meter
connector
LPF: 15kHz
Oscilloscope
HPF: OFF
AG
PTT: ON
AF VTVM
• Wide 4k
2) Test CH: Center
3.4kHz
±
80Hz
PTT: ON
(According to the
, –)
• Narrow
2) Test CH: Center
2.2kHz
±
80Hz
PTT: ON
(According to the
, –)
5. VOX 1
1) Test CH: Center
writing
AG: 1kHz/45mV
6. VOX 10
1) Test CH: Center
writing
AG: 1kHz/4.0mV
Common Section
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
Transmitter Section (Note: The market code of the E3 do not perform “Wide 4k” adjustment)