(No.RA073<Rev.001>)1-51
10. Maximum
Deviation
[Analog Wide]
<PC>
1) Adj item: [Maximum Deviation
(Analog Wide)]
2) Deviation meter
LPF: 15kHz/ HPF: OFF
3) Adj points: 5 points
[Low1], [Low3], [Center2], [High1],
[High3]
4) Press [Transmit] key.
Deviation
meter
Oscilloscope
[
], [
]
Set a fixed value "
491
" for each
adjustment point. Transmit at
each adjustment point and check
that the deviation is within the
Specifications.
Press [Apply All] key for
<PC>
after all adjustment points have
been adjusted.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
4150~4250Hz
<Panel>
1) Adj item: [Aw ADEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
[Analog
Narrow]
<PC>
1) Adj item: [Maximum Deviation
(Analog Narrow)]
2) Deviation meter
LPF: 15kHz/ HPF: OFF
3) Adj points: 5 points
[Low1], [Low3], [Center2], [High1],
[High3]
4) Press [Transmit] key.
Deviation
meter
Oscilloscope
[
], [
]
Set a fixed value "
491
" for each
adjustment point. Transmit at
each adjustment point and check
that the deviation is within the
Specifications.
Press [Apply All] key for
<PC>
after all adjustment points have
been adjusted.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
2050~2150Hz
<Panel>
1) Adj item: [An ADEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
11. P25 High
Deviation
<PC>
1) Adj item: [P25 High Deviation]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 5 points
[Low1], [Low3], [Center2], [High1],
[High3]
4) Press [Transmit] key.
Deviation
meter
Oscilloscope
[
], [
]
Set a fixed value "
500
" for each
adjustment point. Transmit at
each adjustment point and check
that the deviation is within the
Specifications.
Press [Apply All] key for
<PC>
after all adjustment points have
been adjusted.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
2771~2883Hz
<Panel>
1) Adj item: [P1 PDEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
12. P25
H-CPM
Deviation
<PC>
1) Adj item: [P25 H-CPM Deviation]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 5 points
[Low1], [Low3], [Center2], [High1],
[High3]
4) Press [Transmit] key.
Deviation
meter
Oscilloscope
[
], [
]
Set a fixed value "
481
" for each
adjustment point. Transmit at
each adjustment point and check
that the deviation is within the
Specifications.
Press [Apply All] key for
<PC>
after all adjustment points have
been adjusted.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
2995~3117Hz
<Panel>
1) Adj item: [P2 P2DEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC tuning mode
<Panel>: Panel tuning mode