1-46 (No.RA073<Rev.001>)
3. Medium
power check
<PC>
1) Test Channel: 1
Test Signaling Mode: Analog
Signaling: 1
2) Press [Transmit] key.
Power meter
Ammeter
Check
45~55W
16A or less
1) Test Channel: 2
Test Signaling Mode: Analog
Signaling: 1
2) Press [Transmit] key.
1) Test Channel: 3
Test Signaling Mode: Analog
Signaling: 1
2) Press [Transmit] key.
<Panel>
1) CH-Sig: 1-1
2) PTT: ON
Power meter
Ammeter
1) CH-Sig: 2-1
2) PTT: ON
1) CH-Sig: 3-1
2) PTT: ON
3. Low power
check
<PC>
1) Test Channel: 1
Test Signaling Mode: Analog
Signaling: 1
2) Press [Transmit] key.
Power meter
Ammeter
Check
22~28W
13A or less
1) Test Channel: 2
Test Signaling Mode: Analog
Signaling: 1
2) Press [Transmit] key.
1) Test Channel: 3
Test Signaling Mode: Analog
Signaling: 1
2) Press [Transmit] key.
<Panel>
1) CH-Sig: 1-1
2) PTT: ON
Power meter
Ammeter
1) CH-Sig: 2-1
2) PTT: ON
1) CH-Sig: 3-1
2) PTT: ON
4. MIC
sensitivity
check
<PC>
1) Test Channel: 1
Test Signaling Mode: Analog
Signaling: 1
2) AG: 1kHz
3) Press [Transmit] key.
Deviation
meter
Oscilloscope
AG
AF VM
Adjust AG input to get a standard
MOD.
<Standard MOD>
Wide: ±3.0kHz
Narrow: ±1.5kHz
5mV
±1.5mV
<Panel>
1) CH-Sig: 1-1
2) AG: *Same as above
3) PTT: ON
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC test mode
<Panel>: Panel test mode
Unit Parts
Method