1-60 (No.RA073<Rev.001>)
[NXDN
Narrow]
<PC>
1) Adj item: [Squelch Open (NXDN
Narrow)]
2) SSG Output: 12dB SINAD level
at Analog Narrow -1dB
(MOD: 400Hz/±2.5kHz)
3) Adj points: 5 points
[Low1], [Low3], [Center2],
[High1], [High3]
SSG
Distortion
meter
Oscilloscope
[
], [
]
After input signal from SSG;
Press [Apply All] key for
<PC>
after
all adjustment points have been set.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
<Panel>
1) Adj item: [Nn SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
[NXDN Very
Narrow]
<PC>
1) Adj item: [Squelch Open (NXDN
Very Narrow)]
2) SSG Output: 12dB SINAD level
at Analog Narrow -3dB
(MOD: 400Hz/±1.2kHz)
3) Adj points: 5 points
[Low1], [Low3], [Center2],
[High1], [High3]
SSG
Distortion
meter
Oscilloscope
[
], [
]
After input signal from SSG;
Press [Apply All] key for
<PC>
after
all adjustment points have been set.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
<Panel>
1) Adj item: [Nv SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
6. Low RSSI
<PC>
1) Adj item: [Low RSSI (Analog
Narrow)]
2) SSG output: -118dBm (0.28
V)
(MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[Low1], [Low3], [Center2],
[High1], [High3]
SSG
Distortion
meter
Oscilloscope
[
], [
]
After input signal from SSG;
Press [Apply All] key for
<PC>
after
all adjustment points have been set.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
<Panel>
1) Adj item: [An LRSSI]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
7. High RSSI
<PC>
1) Adj item: [High RSSI (Analog
Narrow)]
2) SSG Output: -80dBm (22.4
V)
(MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[Low1], [Low3], [Center2],
[High1], [High3]
SSG
Distortion
meter
Oscilloscope
[
], [
]
After input signal from SSG;
Press [Apply All] key for
<PC>
after
all adjustment points have been set.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
<Panel>
1) Adj item: [An HRSSI]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC tuning mode
<Panel>: Panel tuning mode
Unit Parts
Method
Содержание NX-5700HB
Страница 74: ...MEMO ...
Страница 105: ...MEMO ...
Страница 106: ... No RA073 Rev 001 JKS Printed in Japan JVC KENWOOD Corporation Communications Systems Division ...