(No.RA020<Rev.002>)1-75
4.19 Transmitter Section
Item
Condition
Measurement
Adjustment
Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method
1.
Ramp
up
Offset
1) Adj item:
[RAMPU]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Ramp Up Offset]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Power
meter
Ammeter
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
[PC test mode]
[Automatic Adjust-
ment]
1) Press [Tune Rump
Offset] button.
2) Press [Apply All] but-
ton to store the adjust-
ment value after the
automatic adjustment
has finished.
[Manual Adjustment]
1) Set the adjustment
value to “1”.
2) Increase the adjust-
ment value slowly while
monitoring the offset
monitor value.
3) Set the adjustment
value when the offset
monitor value exceed
“50”.
2.
Ramp
down
Offset
1) Adj item:
[RAMPD]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Ramp Down Off-
set]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Power
meter
Ammeter
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
[PC test mode]
[Automatic Adjust-
ment]
1) Press [Tune Rump
Offset] button.
2) Press [Apply All] but-
ton to store the adjust-
ment value after the
automatic adjustment
has finished.
[Manual Adjustment]
1) Set the adjustment
value to “1”.
2) Increase the adjust-
ment value slowly while
monitoring the offset
monitor value.
3) Set the adjustment
value when the offset
monitor value exceed
“20”.
3.
High
Maxi-
mum
Power
1) Adj item:
[H_MAX]
Adjust:[****]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[High Maximum
Power]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply] but-
ton to store the ad-
justment value.
Power
meter
Ammeter
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
55W
±1W
15A or less
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
Содержание NX-5700