NX-210(G)
37
TROUBLE SHOOTING
Replacing TX-RX Unit
■
TX-RX unit Information
Model Name
Original TX-RX
unit Number
For Service TX-RX
unit Number
NX-210(G) (K2: 18-key)
X57-9270-12
X57-9270-13
■
Method of confi rming “Original TX-RX unit” and
“Service TX-RX unit”
The 0
Ω
resistor (R963) is mounted
on the “0-11” silk print part of the
Service TX-RX unit (X57-9270-13).
X57-927
Component side
R962
R963
X57-927
R962
R963
0-12
0
(None)
0-13
(None)
0
Note:
• The
0
resistor (R962 and R963) is used to differentiate
the destination with a visual check. These are not con-
nected with any PCB pattern; they are specifi cally for pro-
duction control. There is no need to change the mount of
two resistors.
• There is no difference between the schematic diagram of
the Service TX-RX unit (X57-9270-13) and the schematic
diagram of the original TX-RX unit (X57-9270-12). (R962
and R963 are connected with GND (ground) only.)
■
Supplied Accessories of “Service TX-RX unit”
Item (Including Parts Number)
Quantity
NX-210(G) TX-RX Unit (X57-927)
1
Kenwood ESN Label
1
NXDN ESN Label
1
■
“Service TX-RX unit” Data
The following data is written on the service TX-RX unit:
Data Type
Description
Firmware
NX-200(G)/210(G)/300(G) Firmware.
FPU Data
(PC programming mode)
X57-927 (NX-210(G)) K2 type data.
Various Adjustment Data
(PC Test mode)
General adjustment values for the
X57-927 (NX-210(G)).
Kenwood ESN
Model name: NX-210GS
Type: K2
The same number as the Kenwood
ESN label is written.
NXDN ESN
The same number as the NXDN ESN
label is written.
■
After Changing the PCB
1. After changing the printed circuit board, write the up-
to-date Firmware following the instructions in the “RE-
ALIGNMENT - 6.Firmware Programming Mode”.
2. Using the KPG-111D, select your desired item (Model
Name and Frequency) from the Model> Product Informa-
tion menu, then use Program> Write Data to the Trans-
ceiver to write the FPU data (PC Programming mode).
When writing to the transceiver, a Warning Message, cor-
responding to the item selected, appears. Click [OK] to
continue writing the data.
3. Enter Program> Test Mode, then adjust the various ad-
justment data (PC Test Mode) as described in the “AD-
JUSTMENT”.
4. Attach the new labels corresponding to the new printed
circuit board. (Refer to the images on page 38 for label
placement.)
5. If necessary, write the FPU data used by the customer
with the KPG-111D/111DN.
Note:
• When using the ESN Validation function of NXDN Trunk-
ing, the NXDN ESN number changes when the circuit
board is changed (the number is written on the circuit
board); the NXDN Trunking System cannot be accessed.
Use the KPG-110SM on the NXDN Trunking System side
to reprogram the NXDN ESN number.
• When a new printed circuit board is used, the Kenwood
ESN changes, as does the Transceiver Information dis-
play of the KPG-111D/111DN, but this does not have any
effect on the operation of the transceiver.
• If changing to the original Kenwood ESN and NXDN
ESN, please contact our service center.