25
A7 MIG Welder
© Kemppi Oy 2020
2002
INTEGRA
TION GUIDE
5.1.8 Watchdog settings
Watchdog
If your robot supports the watchdog functionality, select
the watchdog
ON
. Otherwise, set this feature
OFF
.
Timeout
Specify a timeout for the watchdog timer by using the
slider. The minimum timeout value is
0.1 s
and maximum
is
5.0 s
. This timeout value specifies how fast the welding
system stops welding if the robot stops sending fieldbus
data. The robot must perform continuous transitions on
the
Watchdog
signal of the digital robot interface within
the timeout period.
5.1.9 Welding system time
Set the welding system time and date by picking up the
date from the pop-up calendar and typing the time to the
particular field. If you want to synchronize the welding
system time with the time of the browser, press the
NOW
button.
After configuring the welding system settings, click on the
Save
button, in the bottom bar, to save all changes.