INTEGRA
TION GUIDE
6.2.25 ToleranceError
This signal function is a common indicator for the tolerance
status signals
CurrentOk
and
WFSpeedOk
. If one of the
values is outside its tolerances, this signal is set (1).
• 0 = Values within tolerances
• 1 = At least one of the values outside the
tolerances
This function is not implemented in the A7 MIG Welder.
The status is always OK (0).
6.2.26 WireStuck
This signal function indicates whether the wire is stuck in
the weld.
• 0 = Wire is OK.
• 1 = Wire is stuck.
This function is not implemented in the A7 MIG Welder.
The status is always OK (0).
6.2.27 GateDoorOpen
This signal function indicates whether the gate door is
open or closed. Opening the gate door always causes an
error (
Error 134: Gate door open
) in the welding system.
Some functions, such as the touch sensor and the wire
feed, can still be used.
• 0 = Gate door closed (OK)
• 1 = Gate door open (error)
6.2.28 PanelLocked
This signal function is deprecated. The status is always 0
(not locked).
6.2.29 LocalRemote
This signal function is deprecated. The status is always 1
(local).
6.2.30 AutoManual
This signal function is deprecated. The status is always 0
(manual).