6

CNA-Series Tankless Heater

 Installation

7/13/2015 

Keltech • 

215-1814 Rev. C; ECN 150010

Plumbing Installation

2

B

Install one union on the water inlet side of the 
heater and another union upstream of the 100 
Mesh (150 micron) y-strainer .
Install one union on the water outlet side of the 
heater and another after the P & T Relief Valve .
Install the pressure relief valve (150 psi) and outlet 
plumbing of heater per code requirements and 
route relief valve discharge to drain . Make sure no 
shutoff valve is between the relief valve discharge 
and the drain . Install hammer arrestor . Ensure 
plumbing is secure and not subject to vibrations .

C

Use 1-1/4" hard copper tubing or pipe as needed . 

A

Install shutoff valve above (upstream of)  
the heater inlet .

CAUTION  To avoid damage to the electronics 

or internal wiring, do not perform 
any brazing or sweat soldering 
inside the enclosure.

NOTICE!  Failure to install proper filtration may 

result in a flow sensor malfunction.

NOTICE!  To avoid water damage, install a drain 

pipe from the pressure relief valve to an 
unrestricted drain.

If end use fixture is not at the highest point in 
the plumbing loop, then an automatic air vent 
valve must be added at the highest point in the 
system or at any drop to eliminate trapped air.

Components Needed:

•  (4) Union 1-1/4"
•  Shutoff Valve
•  Pressure and Temperature Relief Valve (150 psi)
•  Y-Strainer (100 mesh) or Inline Filter (150 microns)
•  (2) Gate or Ball Type Valves
•  Drain pipe
•  Water hammer arrestor (recommended)
•  Elbows, nipples and fittings as needed

B

C

A

31-1/2" 

(800mm)

23-1/2" (597mm)

5-1/2" (140mm)

15-1/4" 

(387mm)

3-3/4" 

(95mm)

6" (152mm)

30" 

(762mm)

12" 

(305mm)

1-1/4" Female NPT 

Outlet

1-1/4" NPT 

Female 

Inlet

Suggested Location For 

Power Entrance . Holes 

Provided By Installer .

Relief 

Valve

Outlet

Inlet

"Y" Strainer

To Drain

Optional 

Fused 

Disconnect

Optional 

Fused 

Disconnect

Maintain area 

above Access 

Panel for height 

"C" to be clear of 

obstructions

Rotate outlet 90˚ 

during installation 

for adequate 

clearance

Suggested Installation Configuration

Components provided by installer unless otherwise specified . 

Reference the product options sections or contact your local Bradley 

Representative for product options .

Access Panel

Dim. "A"

Dim. "B"

Dim. "C"

36kW

60"(1524)

48"(1219)

36"(914)

54kW

60"(1524)

48"(1219)

36"(914)

63kW

72"(1829)

60"(1524)

48"(1219)

72kW

60"(1524)

48"(1219)

36"(914)

108kW

60"(1524)

48"(1219)

36"(914)

126kW

72"(1829)

60"(1524)

48"(1219)

144kW

72"(1829)

60"(1524)

48"(1219)

Dimensions, 
Plumbing 
and Electrical 
Configurations

Содержание CNA-36

Страница 1: ...A 126 CNA 144 CNAR 108 CNAR 126 CNAR 144 Voltage options for models 600V 3 phase 480V 3 phase 415V 3 phase 400V 3 phase 380V 3 phase Table of Contents Pre Installation Information 2 3 Storage Instruct...

Страница 2: ...d this system may result in death or serious injury Make sure that all water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can caus...

Страница 3: ...in the most demanding applications Application Specific Requirements The CNA Series can be used in many different applications that require custom tuning for specific applications to maximize perform...

Страница 4: ...eaters with ENHT freeze protection option If the heater is stored where the temperature could fall below 45 F 7 C the heater must be powered immediately after hydro testing to insure internal freeze p...

Страница 5: ...les 30 762mm 12 305mm 2 51mm 4 102mm 8 204mm 6 7 8 175mm 16 1 4 413mm 3 7 8 99mm 3 4 x 7 16 Slot 6 Places If heater is installed where freezing can occur specify Keltech s ENHT Freeze Protection optio...

Страница 6: ...umbing loop then an automatic air vent valve must be added at the highest point in the system or at any drop to eliminate trapped air Components Needed 4 Union 1 1 4 Shutoff Valve Pressure and Tempera...

Страница 7: ...nal Electric Code could result in injury or death CNA CNAR ELECTRICAL SPECIFICATIONS FOR HEATER Model Voltage Amps kWatts Min Wire Size CNA 363 600D 600 35 36 8 AWG CNA 543 600D 600 52 54 6 AWG CNA 63...

Страница 8: ...e relief valve on outlet if required by local or national plumbing codes If the hot water process is not at the highest point in the plumbing loop then an automatic air vent valve must be added at the...

Страница 9: ...area where freezing temperatures are possible an ENHT Freeze Protection Option is strongly recommended and the heater must be powered at all times to be Freeze Protected If continuous power is not po...

Страница 10: ...temperature Infinity Key Back to Home page Advance Key Advances through parameter prompts Auto Man Off C r71 Turns Control Loop On Manual Off XX X h Pr1 Heater Power no AUt1 Autotune Contact Factory C...

Страница 11: ...ecessary Located on the panel are one 36 63kW or two 72kW 144kW green ready lights When illuminated the safety circuit is engaged and ready for use Heater will not energize heating elements if the inl...

Страница 12: ...ng process are compatible with the heater specifications 5 Verify there is no additional supply of cold water entering the line downstream of the heater Temperature Rise GPM F Models 480 600V Total kW...

Страница 13: ...ntain power at all times or to connect the contacts provided on ENHT heaters correctly to the BMS may result in damage to the heater and void the warranty Please utilize the temperature sensor contact...

Страница 14: ...ing the manual reset safeties to trip Reset bimetal manual safeties and lower heat trace temperature to below 175 F All heaters require filtration of 150 microns or smaller to ensure proper operation...

Страница 15: ...ce circuit breakers or fuses Check the safety interlock door switch to make sure that lack of power is not due to misadjustment or open enclosure door Check system temperature limit control to make su...

Страница 16: ...ezel Bank 1 on the FLCB Bank 3 4 on the front bezel Bank 2 on the FLCB If the light is off and there is power on Check if water temperature is greater than 175 F Decrease water temperatures and restar...

Страница 17: ...osure Purge gas compressed air inlet fitting here EXP2CFPM Installation Notes 1 Any tubing conduit or fittings connected to the Pressurized Enclosure PE must conform to local codes for flammability ra...

Страница 18: ...sure and the protective gas supply The alarm actuator shall be mechanical pneumatic or electrical Electrical alarms and electrical alarm actuators shall be approved for the location in which they are...

Страница 19: ...ay be fitted between the Expo Technologies system and the alarm switch WARNING Never turn on the power without purging first unless you have proved the interior of the PE is gas free and checked that...

Страница 20: ...arms function correctly Check the Relief Valve and any other Spark Arrestors Remove any debris or corrosion or replace the Spark Arrestor Check the condition of the air supply filter element Clean or...

Отзывы: