CNA-Series Tankless Heater

 Installation

7/13/2015 

Keltech • 

215-1814 Rev. C; ECN 150010

Storage Instructions

NOTICE! Keep Keltech Electric Tankless Water Heaters stored in original packaging until installation.  

Recommended storage criteria: 

Store Keltech Electric Tankless Water Heaters where temperatures exceed 35ºF (2º C) at all times .
Indoor storage is recommended .
Minimize excessive on-site transport to reduce risk of shock and impact damage . 

Alternate storage: 

If in the original crate, Keltech Electric Tankless Water Heaters will withstand outside storage for approximately 1 
month in most climates . Crate may not be capable of protecting the heater if left outside longer than this time frame .
If the Keltech Electric Tankless Water Heater is stored in an outdoor environment, care should be taken to protect the 
heaters from:

•  Rain or other falling precipitation via tarp or other waterproof media .
•  Runoff and accumulation of groundwater from any source that may exceed 1 inch . 

NOTICE!  For heaters with ENHT freeze protection option: If the heater is stored where the temperature 

could fall below 45°F(7°C), the heater must be powered immediately after hydro testing to insure 
internal freeze protection components are activated. Once the heater is installed and the on-site 
plumbing has been hydro tested, the power supply must remain constant until the risk of freeze is 
eliminated. If this is not possible, do not allow the heater to remain full of water.  The heater must 
be drained.  Freezing of the heater can cause serious damage.  Follow notes in Start Up Check List 
section following an electrical lockout/tagout procedure.

Packaging

Crates are constructed from 3/4" OSB . 
Crate dimensions approx: 82" x 48" x 24" (2083mm x 1219mm x 610mm)
Crates should not be stacked more than 2 high .
All crates must be stacked evenly and horizontally .
Safety issues related to packaging:

•  Product should be transported with the care associated to packages labeled “FRAGILE” even if packaging is not 

marked accordingly .

•  Standard safety procedures for forklift transport and large items less than 1000lbs should be followed at all times . 
•  When stored, crate must be supported in entirety of its length and width .

Содержание CNA-36

Страница 1: ...A 126 CNA 144 CNAR 108 CNAR 126 CNAR 144 Voltage options for models 600V 3 phase 480V 3 phase 415V 3 phase 400V 3 phase 380V 3 phase Table of Contents Pre Installation Information 2 3 Storage Instruct...

Страница 2: ...d this system may result in death or serious injury Make sure that all water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can caus...

Страница 3: ...in the most demanding applications Application Specific Requirements The CNA Series can be used in many different applications that require custom tuning for specific applications to maximize perform...

Страница 4: ...eaters with ENHT freeze protection option If the heater is stored where the temperature could fall below 45 F 7 C the heater must be powered immediately after hydro testing to insure internal freeze p...

Страница 5: ...les 30 762mm 12 305mm 2 51mm 4 102mm 8 204mm 6 7 8 175mm 16 1 4 413mm 3 7 8 99mm 3 4 x 7 16 Slot 6 Places If heater is installed where freezing can occur specify Keltech s ENHT Freeze Protection optio...

Страница 6: ...umbing loop then an automatic air vent valve must be added at the highest point in the system or at any drop to eliminate trapped air Components Needed 4 Union 1 1 4 Shutoff Valve Pressure and Tempera...

Страница 7: ...nal Electric Code could result in injury or death CNA CNAR ELECTRICAL SPECIFICATIONS FOR HEATER Model Voltage Amps kWatts Min Wire Size CNA 363 600D 600 35 36 8 AWG CNA 543 600D 600 52 54 6 AWG CNA 63...

Страница 8: ...e relief valve on outlet if required by local or national plumbing codes If the hot water process is not at the highest point in the plumbing loop then an automatic air vent valve must be added at the...

Страница 9: ...area where freezing temperatures are possible an ENHT Freeze Protection Option is strongly recommended and the heater must be powered at all times to be Freeze Protected If continuous power is not po...

Страница 10: ...temperature Infinity Key Back to Home page Advance Key Advances through parameter prompts Auto Man Off C r71 Turns Control Loop On Manual Off XX X h Pr1 Heater Power no AUt1 Autotune Contact Factory C...

Страница 11: ...ecessary Located on the panel are one 36 63kW or two 72kW 144kW green ready lights When illuminated the safety circuit is engaged and ready for use Heater will not energize heating elements if the inl...

Страница 12: ...ng process are compatible with the heater specifications 5 Verify there is no additional supply of cold water entering the line downstream of the heater Temperature Rise GPM F Models 480 600V Total kW...

Страница 13: ...ntain power at all times or to connect the contacts provided on ENHT heaters correctly to the BMS may result in damage to the heater and void the warranty Please utilize the temperature sensor contact...

Страница 14: ...ing the manual reset safeties to trip Reset bimetal manual safeties and lower heat trace temperature to below 175 F All heaters require filtration of 150 microns or smaller to ensure proper operation...

Страница 15: ...ce circuit breakers or fuses Check the safety interlock door switch to make sure that lack of power is not due to misadjustment or open enclosure door Check system temperature limit control to make su...

Страница 16: ...ezel Bank 1 on the FLCB Bank 3 4 on the front bezel Bank 2 on the FLCB If the light is off and there is power on Check if water temperature is greater than 175 F Decrease water temperatures and restar...

Страница 17: ...osure Purge gas compressed air inlet fitting here EXP2CFPM Installation Notes 1 Any tubing conduit or fittings connected to the Pressurized Enclosure PE must conform to local codes for flammability ra...

Страница 18: ...sure and the protective gas supply The alarm actuator shall be mechanical pneumatic or electrical Electrical alarms and electrical alarm actuators shall be approved for the location in which they are...

Страница 19: ...ay be fitted between the Expo Technologies system and the alarm switch WARNING Never turn on the power without purging first unless you have proved the interior of the PE is gas free and checked that...

Страница 20: ...arms function correctly Check the Relief Valve and any other Spark Arrestors Remove any debris or corrosion or replace the Spark Arrestor Check the condition of the air supply filter element Clean or...

Отзывы: