Kele K-O2 Скачать руководство пользователя страница 15

K-O2 Oxygen Sensor 

5/20/2022 

Kele, Inc. • 3300 Brother Blvd. • Memphis, TN  38133 

Page 13 

 

www.kele.com

 

 

W

ARRANTY

 

7.1  D

URATION

 

Component / Class 

Duration of Warranty 

Enclosure & main board 

7 years 

Sensor modules 

1 year 

7.2  L

IMITED WARRANTY AND REMEDIES

KELE warrants to Buyer that for the duration stated in the “Duration of Warranty” section above from the date of 
shipment of Products to the Buyer that Products will substantially conform to the product specifications agreed to 
by KELE.  This warranty is not transferable. 

This warranty does not cover: 

 

Defects due to misuse, abuse, or improper or inadequate care, service or repair of Products;  

 

Defects due to modification of Products, or due to their alteration or repair by anyone other than KELE;  

 

Problems that arise from lack of compatibility between KELE's Products and other components used with 
those Products or the design of the product into which Products are incorporated.   

Buyer is solely responsible 

for determining whether Products are appropriate for Buyer's purpose

and for ensuring that any product 

into which Products are incorporated, other components used with KELE's Products, and the purposes for 
which Kele's Products are used are appropriate and compatible with those Products.

 

Unless KELE agrees otherwise, to obtain service under this warranty, Buyer must pack any nonconforming Product 
carefully, and ship it, postpaid or freight prepaid, to Kele, Inc. at  

3300 Brother Blvd. • Memphis, TN  38133 

before the expiration of the warranty period.  Buyer must include a brief description of the nonconformity.  Any 
actions for breach of this warranty must be brought within one year of the expiration of this warranty. 

If Kele determines that a returned Product does not conform to this warranty it will, at Kele’s sole discretion, either 
repair or replace that Product, and will ship the Product back to Buyer free of charge.  At KELE's option, KELE may 
choose to refund to Buyer the purchase price for a nonconforming Product instead of repairing or replacing it. 

 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.  KELE EXPRESSLY DISCLAIMS 
ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE.   

KELE IS NOT RESPONSIBLE IN ANY WAY FOR DAMAGE TO A PRODUCT, PROPERTY DAMAGE OR PHYSICAL 
INJURY RESULTING IN WHOLE OR IN PART FROM (1) IMPROPER OR CARELESS USE, (2) UNAUTHORIZED USE 
OR MODIFICATIONS, OR (3) OTHER CAUSES BEYOND KELE'S CONTROL.   

IN NO EVENT IS KELE LIABLE TO THE BUYER OR ANY OTHER PERSON FOR COST OF PROCUREMENT OF 
SUBSTITUTE GOODS, LOSS OF PROFITS, OR FOR ANY OTHER SPECIAL, INCIDENTAL OR CONSEQUENTIAL 
DAMAGES. 

Содержание K-O2

Страница 1: ...mphis TN 38133 Revision 5 20 2022 www kele com 90 0007 00A K O2 xx Oxygen Sensor Transmitter and Two Stage Alarm Controller User s Manual K O2 H5 5 year sensor K O2 H10 10 year sensor K O2 S5 5 year s...

Страница 2: ...ional Description 5 4 1 Special Modes 6 4 2 Warning Ventilation and Alarm Conditions 7 4 3 Setting Ventilation and Alarm Thresholds 7 4 4 Concentration Reporting 7 5 Sensor Calibration 7 5 1 Calibrati...

Страница 3: ...sor life K O2 H5 Lockable hinged enclosure with 10 year sensor life K O2 H10 Table 1 K O2 family Part numbers All K O2 xx models are shipped with either 5 year life K O2 x5 or 10 year life K O2 x10 fa...

Страница 4: ...ply separate transformer not required Power Consumption 5W Control Relays 2 separate SPDT line voltage capable relays for warning ventilation and alarm outputs UL rated 10 Amps max at 120 277 VAC or 3...

Страница 5: ...water entry DO NOT USE THE VENT HOLES FOR WIRE ENTRY 1 This unit is designed to mount to a rigid vibration free surface near the middle of the area to be monitored about 5 feet above the floor 2 It s...

Страница 6: ...of the terminal and returns to the terminal The oxygen sensor output is provided at the terminal highlighted in Figure 3 Analog output connection has polarity as labeled on the controller silkscreen...

Страница 7: ...to the COM location of screw terminal 5 Plug the relay output screw terminal back into the correct location on controller board 3 3 POWER CONNECTION The K O2 has a fully isolated unpolarized power inp...

Страница 8: ...a second contact closure is operated typically to trigger an alarm The gas sensor is a calibrated module that can be replaced with minimal effort when it reaches end of life EOL while leaving the main...

Страница 9: ...ormation When the concentration of oxygen falls below its configured warning ventilation threshold the WARNING VENTILATION relay output is activated When the concentration falls below the alarm thresh...

Страница 10: ...adequate and requires no calibration gas All that s required is the certainty of fresh air around the sensor For accuracy at lower oxygen percentages a zero calibration before the span calibration is...

Страница 11: ...rictor fitted to the narrow end of the cal cap at a pressure of 10 psi 5 2 CALIBRATION GAS CONNECTION A schematic of the calibration gas tubing connection between the regulator and the calibration cap...

Страница 12: ...tion gas has been removed the calibration has been applied and the unit is in standby for two minutes while the sensor re equilibrates to the ambient atmosphere before normal operation resumes The cal...

Страница 13: ...turns to steady GREEN OR 3B If NOT successful blinking RED The most likely causes of span gas sampling failure are Insufficient gas flow or leaks around the calibration adapter not completely immersin...

Страница 14: ...n in To replace a sensor module with a new factory calibrated one follow the steps below 1 Open the controller s front cover 2 Unplug the controllers power connector refer to Figure 6 3 Unplug the sen...

Страница 15: ...patible with those Products Unless KELE agrees otherwise to obtain service under this warranty Buyer must pack any nonconforming Product carefully and ship it postpaid or freight prepaid to Kele Inc a...

Страница 16: ...tect common failures If a failure is detected the front cover status LED will blink slowly RED the warning relay will be activated and the concentration reporting analog output will stay at 4 mA until...

Отзывы: