Keithley DAS-1700 Series
Using the DAS-1700 Series with DriverLINX
•
55
How to set up the DAS-1700 Series to sample on an arbitrary list of channels.
Analog Input Channel Gains
Each channel in a channel scan list has a gain code property to select the pre-
amplifier gain when sampling that channel. The following tables show the
correspondence between the gain multiplier, the maximum input signal range, and the
gain code for each input range. Note: DriverLINX uses a negative (-) gain multiplier
to signify a bipolar (
±
) range.
You should be aware that using multiple channels or non-unity gains reduces the
maximum sample rate. Consult your hardware manual for details.
DAS-1701 Models
Gain
Range
Gain Code
-1
±5 V
0
-5
±1 V
1
-50
±100 mV
2
-250
±20 mV
3
1
0 … 5 V
4
5
0 … 1 V
5
50
0 … 100 mV
6
250
0 … 20 mV
7
Gains, Ranges, and Hardware Gain Codes for DAS-1701 Models.